ESPECIFICACIONES TÉCNICAS
ESPECIFICACIONES
Nivel de salida
Rango Dinámico
THD + Ruido
Tiempo de Latencia
Fuente de alimentación
CARACTERÍSTICAS
Entradas de Audio
Entradas Sense
Salidas de Audio
Procesado
Panel Frontal
Panel Trasero
Memoria FLASH
Dimensiones y Peso
User Controls
Selección del sistema
Configuración del sistema
Protección
Retardos
Headroom
Ganancia de Salida
Lectura Ganancia del Amplificador
Mute/Solo
Save/Recall
Array EQ
Security Mode
Certificados
NX242 MANUAL DEL USUARIO LOAD2_45
FECHA: 15/10/2008
NOTA DE APLICACIÓN: ENVÍO AL SUB DESDE AUXILIAR
Procesador digital NX242 TDcontroller
+28 dBu Max. con 600 Ohms carga
Todos los canales = 110dB
Typical 0.005% flat setup (Max 0.01%@1000Hz@ 28dBu)
2.2ms on a flat setup
115-230 Volts 50-60Hz continuous operation (operating range 90-264V)
Dos entradas L&R Heavy Duty Audio, conversores de 24bit; Electronically balanced and
floating, 20kOhm. CMMR=80dB. Dos conectores XLR 3.
4 Amplifier Sense Inputs (LF mono, MF/HF L&R),Floating 150 kΩ. 18 bit converters. 8
Pole Removable Strip Terminal.
4 Audio Outputs. 24 bit converters,Electronically balanced, 50 Ohms, 4 XLR-3M
connectors
24 bit data with 48-bit accumulator. 100MIPS, NXtension Expander Board 100MIPS
opcional
Menu A and Menu B buttons.16 characters by 2 lines display. Select Wheel & Enter
button (
). IN Clip – DSP Clip red LED's Speaker Protection yellow LED for each
channel. Individual Mute/Solo buttons and red LED for each channel. Amp. Sense & Peak
(green & red) LED's for each channel
On/Off Mains switch; mains IEC socket; RS232 serial communications connector;
Expansion slot for processor extension card.
Upgrade for software improvement, new cabinet set-ups available on NEXO web site
www.nexo.fr
1U 19" Rack - 230 mm (9") Depth.
3.8kg (8.8lbs) net
Allows control from all NEXO ranges.
Within the selected range, allows the cabinet to be set for passive or active mode,
aux,mono or stereo subs, wedge or FOH operations depending on system selected. Up to
80 factory pre-sets.
Peak Limiter, Displacement and Temperature protection on every channel; Physio control
of the Protection limiter & compressors Soft Clip Automatic tracking of amplifier clip point.
Up to 150m (465 ft.) of delay in 10cm (.4in ) steps; on Sub channel, Main channels or Sub
+ Main linked
Allows to adjustment the input sensitivity while keeping an overall unity gain
Ganancia Global e inter-canal de 6dB en pasos de 0.5dB.
Permite comprobar la ganancia del amplificador a través de programa
Changes front panel buttons from Channel Mute to Solo
Set-up Stores up to 10 user set-ups; On- the-fly recall, without mute or glitches for instant
comparison.
LF or HF shelving filter to compensate ground or stacking effects, +/-6dB, frequency
factory tuned.
Password protegido en modo de "Sólo Lectura".
CE mark (EN 60065-1998, EN55103-1996), cULus approved (
scheme
UL60065)
, FCC part15 compliant, CB