Montaje Y Desmontaje Del Actuador - Cepex PVC-U Serie Manual De Instrucciones

Válvula de bola- encolar hembra c/actuador eléctrico
Tabla de contenido

Publicidad

Mount and dismantle the actuator

Montaje y desmontaje del actuador

If the actuator or the valve needs to be replaced, proceed
as follows:
1.
Move the ball valve to the closed position.
2.
Depressurise and drain the plant or the plant compo-
nent.
3.
Depressurise the control medium.
4.
Remove the control medium line(s) from the actuator.
5.
Remove the screws (A).
6.
Separate the electric actuator (2) with the mounting
clamp (4) from the bare shaft valve (1).
7.
Remove the screws (B) in order to dismantle the actua-
tor from the mounting clamp.
8.
In the case that the actuator needs to be replaced by a
handle, also remove the coupling bush (3).
In order to assemble a new actuator or a new valve, pro-
ceed in opposite direction to the description above.
CEPEX EXTREME SERIES DATASHEETS
Si es necesario reemplazar el actuador o la válvula, proceder
de la siguiente manera:
1.
Mover la válvula a posición de cerrado.
2.
Despresurizar y dreanr el sistema.
3.
Despresurizar el medio de control.
4.
Retirar las líneas del medio de control del actuador.
5.
Retirar los tornillos (A).
6.
Separar el actuador eléctrico (2) con la brida de fijación (4)
de la válvula (1).
7.
Retirar los tornillos (B) a fin de separar el actuador de la
brida de fijación.
8.
En caso de querer sustituir el actuador por una maneta,
retirar también el casquillo de conexión (3).
Para montar un nuevo actuador o una nueva válvula, proce-
der a realizar los pasos anteriores en sentido contrario.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pvc-u ball

Tabla de contenido