* For the address, size, and checksum, refer to "Examples of system exclusive messages
and calculating the checksum" (P. 206).
* Transmission of consecutive addresses is not possible.
3. Data reception (Sequencer section)
1 Messages recorded during recording
Channel voice messages
Note Off
status
2nd byte
8nH
kkH
9nH
kkH
Note On
status
2nd byte
9nH
kkH
vv=Note On velocity:01H - 7FH (1 - 127)
Polyphonic Aftertouch
status
2nd byte
AnH
kkH
Control Change
status
2nd byte
BnH
kkH
kk=control number: 00H–78H (0–120)
Program Change
status
2nd byte
CnH
ppH
pp=Program number:00H–7FH (prog.1–prog.128)
Channel Aftertouch
status
2nd byte
DnH
vvH
Pitch Bend Change
status
2nd byte
EnH
llH
mm,ll=Pitch Bend value:00 00H–40 00H–7F 7FH (-8192–0–+8191)
Channel Mode messages
All Sound Off (Controller number 120)
status
2nd byte
BnH
78H
Reset All Controllers (Controller number 121)
status
2nd byte
BnH
79H
Omni Off (Controller number 124)
status
2nd byte
BnH
7CH
* The same processing will be done as when an All Note Off message is received.
Omni On (Controller number 125)
status
2nd byte
BnH
7DH
* The same processing will be done as when an All Note Off message is received.
Mono (Controller number 126)
status
2nd byte
BnH
7EH
mm=mono number: 00H–10H (0–16)
* The same processing will be done as when an All Note Off message is received.
3rd byte
vvH
00H
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
mmH
3rd byte
00H
3rd byte
00H
3rd byte
00H
3rd byte
00H
3rd byte
mmH
Poly (Controller number 127)
status
2nd byte
BnH
7FH
* The same processing will be done as when an All Note Off message is received.
System Exclusive messages
status
data byte
F0H
iiH, ddH, ......, eeH
F0H:
System Exclusive message status
ii = ID number:
This is the ID number (manufacturer ID) that specifies the
manufacturer whose exclusive message this is. Roland's manufacturer ID is 41H.ID
numbers 7EH and 7FH are defined in an expansion of the MIDI standard as Universal Non-
realtime messages (7EH) and Universal Realtime Messages (7FH).
dd,..., ee = data:
00H–7FH (0–127)
F7H:
EOX (End Of Exclusive)
2 Messages not recorded during recording
Channel Mode messages
Local On/Off (Controller number 122)
status
2nd byte
BnH
7AH
vv=value:
00H,7FH (Local off, Local on)
All Note Off (Controller number 123)
status
2nd byte
BnH
7BH
* When an All Note Off message is received, all notes of the corresponding channel that
are on will be sent Note Off's, and the resulting Note Off messages will be recorded.
3 Messages acknowledged for synchronization
System Common messages
Song Position Pointer
status
2nd byte
F2H
mmH
mm,ll=value: 00 00H–7F 7FH (0–16383)
System Realtime messages
Timing Clock
status
F8H
* This message will be received if the Sync Mode parameter is SLAVE.
Start
status
FAH
* This message will be received if the Sync Mode parameter is SLAVE or REMOTE.
Continue
status
FBH
* This message will be received if the Sync Mode parameter is SLAVE or REMOTE.
Stop
status
FCH
* This message will be received if the Sync Mode parameter is SLAVE or REMOTE.
MIDI Implementado
3rd byte
00H
status
F7H
3rd byte
00H
3rd byte
00H
3rd byte
llH
199