Technical data

Power Pack
Max. output, kW
Rated current 3-phase, A
Rated current 1-phase, A
3-phase voltage in, V
1-phase voltage in, V
Power supply
3-phase
1-phase
Weight, kg/lbs
Power pack
Water cooling
Water pressure - max, bar/PSI
Water coolant flow min., l/min
Max cooling water temperature at 3,5 l/min, °C
Control system
Control type
Signal transmission
Typical generator operation cases
PP220, power output Generator output voltage (V)
Full power
3-phase
Decreased power
1-phase
Dimensions

Recommended cable dimensions

NOTICE! Good motor performance depends on proper voltage. Extension cables that are too long and/or which have
a gage that is too small, reduce power to the motor under load, resulting in reduced output or malfunctions.
TECHNICAL DATA
PP220
6,5
10
15/16
380-400, 50 Hz
220-240, 50 Hz
L1+L2+L3+N+PE/L1+L2+L3+PE
L+N+PE
10,8/23,8
7/101,5
3,5
25
Remote control
Wireless/cable
3x380, 3x400
220-240
Minimum recommended
generator output (kVA)
10
5
English – 23