Ribind PARK 230V fw08 Manual Del Usaurio página 23

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

RELAY AND MOTOR COMMAND
K1 => Opening direction command
K2 => Closure direction command
Q4 => TRIAC - Opening and Closing motor command
Q5 => Blinker command
POINT B - SETTINGS
DIP 1 (ON)
MOTOR ROTATION DIRECTION CHECK (See Point C)
DIP 2 (ON)
PROGRAMMING (See Point D)
DIP 1-2
STORING/ERASING RADIO CODES FOR MOTOR
CONTROL (See Point E)
DIP 3
ON
- Automatic Closing ENABLED (max 5 min)
OFF - Automatic Closing DISABLED
DIP 4
ON
- AUTOMATIC Radio Receiver Command
OFF - STEP BY STEP Radio Receiver Command
DIP 5
ON
- AUTOMATIC single pulse command (K BUTT.)
OFF - STEP BY STEP single pulse command (K BUTT.)
DIP 6
ON
- Operation in PARK MODE
OFF - Operation in NORMAL MODE
WARNING: The PARK MODE enables or disables some features and commands:
If NORMAL MODE is enabled, OPEN2 command, OK CLOSE command and TLC
(Traffic Light Control) input, are not enabled.
If PARK MODE is enabled all commands are enabled.
DIP 7
ON
- boom arm locking magnet ENABLED (ACQ9080 or ACQ9081 optional
cards)
OFF - courtesy light operation ENABLED (ACQ9080 or ACQ9081 optional
cards)
If none of the optional card is connected, turn DIP7 to OFF.
DIP 8
ON
- in PARK MODE the OPEN2 button is always enabled
OFF - in PARK MODE the OPEN2 button works if there is no vehicle on the
magnetic sensor connected to the TLC input (TLC contact opened).
DIP 9
ON
- safety strip self-test ENABLED
OFF - safety strip self-test DISABLED
DIP 10 ON
- after the blackout the boom arm automatically closes
OFF - after the blackout the boom arm remains still on the point it was when
blackout occurred
DIP 11 ON
- for the INDUSTRIAL Three-phase barrier (code AA52001) with PARK R2
(BA03206) configuration
OFF - for the barriers in according to table 1
DIP 12 OFF - Operation control with low speed limit switches connected
separately (see photo 5) LIMIT SWITCHES FIXED ON THE
BALANCE SPRING BARS
ON
- Operation control with low speed limit switches connected
in parallel (see photo 6) LIMIT SWITCHES FIXED ON THE
DRIVING SHAFT (the low speed wire can be connected to
LSSC or LSSO).
OFF - Operation control with low speed limit switches separately
connected (see photo 7). LIMIT SWITCHES WITH CONTROL
PANEL
ON
- to instal the PARK 230V control panel as a replacement of the
EUROBAR control panel on NORMAL barriers.
DIP 13 ON
- Blinker operation with intermittent power supply
OFF - Blinker operation with fixed power supply
DIP 14 - selecting type of barrier operation (see table 1)
DIP 15 - selecting type of barrier operation (see table 1)
DIP 16 - selecting type of barrier operation (see table 1)
DIP 14 DIP 15 DIP 16 STANDARD BARRIER
OFF
OFF
OFF
RAPID S code AA50070 with a 3m boom arm code ACG8501
OFF
OFF
ON
RAPID S code AA50070 with a 4m boom arm code ACG8502
ON
OFF
ON
RAPID S code AA50070 with a 5m boom arm code ACG8503
ON
OFF
OFF
RAPID N code AA50080
OFF
ON
OFF
RAPID PARK code AA50041
ON
ON
OFF
NORMAL code AA50000
OFF
ON
ON
Available
ON
ON
ON
Available
TABLE 1
LOW SPEED REGULATOR (ONLY FOR RAPID S, RAPID N AND RAPID PARK
BARRIERS)
Slow-speed regulations are carried out by turning the Trimmer LOW SPEED, it permits
to vary the speed of the motor in approaching to the closing position (turning clockwise
to increase the motor speed). This kind of regulation is not available in approaching to
the opening position.
The starting of slowing down is controlled automatically by the limit switches at
approximately 30° before reaching the complete opening and closing position.
LED WARNING
DL1 - Programming activated (red)
DL2 - Stop contact (red)
DL3 - Barrier opening (green)
DL4 - Barrier closing (red)
DL5 - Photocells contact (red)
DL6 - Safety strip contact (red)
DL7 - Closing limit switch contact (red)
DL8 - Opening limit switch contact (red)
DL9 - Radio programming activated (green)
POINT C - CALIBRATING LOW SPEED MOTOR
This check is meant to facilitate the installer during the start-up of the system or for any
other future controls:
1 - Turn DIP1 to ON, the red led DL1 starts blinking
2 - Press the PROG button and hold it (movement is now performed in "man present"
mode, open-stop-close-stop-open etc.).
If the GREEN led DL3 is on, the boom arm opens. If the RED led DL3 is on, the boom
arm closes.
3 - Carry out the slow-down speed calibration:
- Turn the LOW SPEED trimmer to minimum
- Press and hold the PROG button pressed
- Check whether the low speed has been enabled once LSSC and LSSO limit
switches have been reached
- Adjust the LOW SPEED trimmer
WARNING: Make sure the motor is powerful enough to move the bar during closure.
Otherwise increase the value set on the LOW SPEED trimmer until it reaches the ideal
operation condition.
4 - Turn DIP1 to OFF, the red LED DL1 turns off.
During Point C procedure the safety-strip and photocells are not enabled.
POINT D - TIME PROGRAMMING
1 - Close the barrier completely.
2 - Turn the DIP 2 to ON, the red led DL1 starts blinking.
3 - Press the PROG button, the boom arm opens.
4 - Once opening has been completed, the boom arm stops. The gap of time between
now (stop of the motor) and the next pressing of the PROG button (see step 5 below)
will be then stored as waiting time (max 5 minutes) for Automatic Closing feature.
5 - Press the PROG button, the boom arm closes and the Automatic Closing time is
stored (see DIP3 function to enable or disable the Automatic Closing feature).
6 - The red LED DL1 turns off.
7 - Turn DIP2 to OFF.
During Point D procedure, the safety devices (photocells and safety strip) are
active.
POINT E - RADIO CODE STORING
(MAX 60 CODES)
1 - The boom arm must be completely closed.
2 - Turn DIP1 to ON position, the red LED DL1 starts blinking quickly
3 - Immediately, turn also DIP2 to ON position, the red LED DL1 starts blinking slowly.
Each code must be programmed within 10 seconds.
4 - Press one of the buttons on the remote control (usually channel A). If the remote
control is stored correctly green LED DL9 (on the PARK 230V CRX control board) emits
a flash. The 10 seconds' time within storing radio codes is automatically renewed to
allow the string of the next remote control.
5 - To end radio code storing either press PROG button or let 10 seconds pass. The LED
DL1 shall stop blinking.
6 - Turn DIP1 to OFF position.
7 - Turn DIP2 to OFF position.
23