STEP 8: BIND PIPES & DUCTING
1. Bind the connection pipe, power cord, and drainage hose using the included bands.
indoor unit
2. At the end of the binding, ensure the electrical cord and drain hose are bound
independently and never kinked.
3. Never cross or intersect the electrical wire and the control wire; this can lead to
interference during operation.
4. The gas and liquid pipes should be bound separately.
STEP 9: HANG THE INDOOR UNIT
indoor
wall pipe
1. Place the bound pipes inside the wall pipe and pass them through the wall hole.
2. Hang the interior unit on the wall mounting frame.
3. Stuff the gaps in the wall with sealing gum or foam.
4. Attach the wall pipes
5. Verify that the indoor unit is firmly and securely mounted to the wall.
indoor and
outdoor power cord
gas
pipe
liquid pipe
band
drain hose
outdoor
sealing gum
connection pipe
indoor power cord
lower hook of
wall-mounting frame
–17–
drain hose
band
upper hook