2. TESTING OPERATION

Cycle through the power mode by turning the unit on with the remote control or
thermostat.
Press the mode button to cycle between Auto, Cool, Dry, Fan, and heat modes to
verify functional operation.
Note that if the outdoor ambient temperature is below 16°, the air conditioner can
not operate.
COOLING DUCT SPECIFICATIONS
Standard duct length:
Minimum duct length:
Maximum duct length:
Maximum elevation change:
REFRIGERANT CHARGING TABLE
In any case where the duct length is 10 meters or longer; 5ml of refrigerant should be
added per 5 meters of duct length.
Diameter of connection pipe
Liquid pipe(mm)
Ø6mm (1/4")
Ø6mm (1/4") or
Ø9.52mm (3/8")
Ø12mm
Ø16mm
Ø19mm
Ø22.2mm
5m
3m
25m
10m
Gas pipe(mm)
Ø9.52mm (3/8")
or Ø12mm (1/2")
Ø16mm (5/8")
or Ø19mm
Ø19mm
or Ø22.2mm
Ø25.4mm
or Ø31.8mm
–19–
Outdoor unit throttle
Cooling only
(g/m)
15g/m
15g/m
30g/m
60g/m
250g/m
350g/m
Cooling &
heating (g/m)
20g/m
50g/m
120g/m
120g/m
250g/m
350g/m