Beretta MySmart 28 C.S.I. Para El Instalador página 19

Ocultar thumbs Ver también para MySmart 28 C.S.I.:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MULTIGAS TABLE
DESCRIPTION
Lower Wobbe index (at 15°C-1013 mbar)
Net Calorific Value
Supply nominal pressure
Supply minimum pressure
MySMART 28 C.S.I.
Diaphragm - number of holes
Diaphragm - diameter of holes
Burner diameter
Burner length
HC maximum gas capacity
DHW maximum gas capacity
HC minimum gas capacity
DHW minimum gas capacity
Number of fan rotations with slow ignition
Maximum number of heating fan rotations
Maximum domestic hot water fan rotations
Minimum number of heating fan rotations
Minimum number of DHW fan rotations
The data indicated must not be used to certify the system; for certification, use the data indicated in the "System handbook" measured during
first ignition.
All the pressure values are measured with the compensation socket disconnected.
MySMART 28 C.S.I.
Seasonal ambient heating energy efficiency class
Parameter
Nominal output
For boilers for ambient heating and combined: Useful heat output
At nominal heat output and at
high temperature operation (*)
At 30% of the nominal heat output and
at low temperature operation (**)
Auxiliaries electrical consumption
At full load
At partial load
In Standby mode
For combined heating appliances
Declared load profile
Daily electrical energy consumption
Annual electrical energy consumption
(*) High temperature operation: 60°C at boiler return line and 80°C at boiler delivery line.
(**) Low temperature operation: For condensing boilers 30°C, for low temperature boilers 37°C, for other heating appliances 50°C return line
temperature.
NOTE (if the external probe or the control panel, or even both devices, are present in the boiler)
With reference to the Delegated Regulation (EU) No. 811/2013, the information in the table can be used for completing the product data sheet and the
labeling for room heating appliances, for mixed heating appliances, for all those appliances for enclosed space heating, for temperature control devices
and solar devices:
COMPONENT
EXTERNAL PROBE
CONTROL PANEL
EXTERNAL PROBE + CONTROL PANEL
A
Symbol
Value
Unit
Pnominale
20
kW
P4
19.6
kW
P1
6.6
kW
elmax
29,0
W
elmin
10.4
W
PSB
2.4
W
XL
Qelec
0,139
kWh
AEC
30
kWh
MJ/m
S
3
MJ/m
S
3
mbar (mm W.C.)
mbar (mm W.C.)
No.
ø mm
1x4,7 flap+1x4,2 free
mm
mm
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
rpm
rpm
rpm
rpm
rpm
Water heating energy efficiency class
Parameter
Seasonal ambient heating
energy efficiency
For boilers for ambient heating and combined: efficiency
At nominal heat output and at
high temperature operation (*)
At 30% of the nominal heat output and
at low temperature operation (**)
Other parameters
Heat loss in standby mode
Pilot flame energy consumption
Annual energy consumption
Internal sound output level
Nitric oxide emissions
Heating water energy efficiency
Daily fuel consumption
Annual fuel consumption
Class
II
V
VI
Methane gas
(G20)
45,67
34,02
20 (203,9)
10 (102,0)
2
1x3,4 flap+1x3,25 free
63
95
2,12
2,96
0,30
0,30
3.700
4.500
6.100
1.200
1.200
Symbol
Value
ηs
94
η4
88.6
η1
98,7
Pstby
26.0
Pign
QHE
39
LWA
51
NOx
29
ηwh
85
Qfuel
22,827
AFC
17
Bonus
MySMART C.S.I.
Propane
(G31)
70,69
88
37 (377,3)
-
2
63
95
1,55
2,17
0,31
0,31
3.700
4.500
6.100
1.500
1.500
A
Unit
%
%
%
W
-
W
GJ
dB
mg/kWh
%
kWh
GJ
2%
3%
4%
19

Publicidad

Tabla de contenido
loading

Tabla de contenido