RS02
- the gate/barrier opens and closes completely and the display shows 4 dots (reading the current thresholds)
- when completely closed, the display shows END,indicating that the travel has been saved correctly.
8.4 PAR:
Used to modify all the parameters of the control unit, press the UP button until PAR appears on the display, confirm with the OK button to dis-
play the list of parameters, the display will show P 01 (parameter number 1), the UP or DOWN button lets you scroll through the list of parameters (see
parameter table).
x4
Parameter table
Number
of parameter Description
P01
Enables automatic closing
P02
Sets the automatic closing time
P03
AP/CH input operation
P04
Pre-flash
P05
Closing after photocell disengage-
ment
P06
Type of safety device connected to
the STPA input
P07
AUX output operating mode
P08
Enables photocell control
P09
Slowdown distance when closing
P10
Slowdown distance when opening
P11
Opening speed
P12
Closing speed
P13
Opening deceleration speed
P14
Closing deceleration speed
P15
Motor force
P16
Intensity of stopping with opening
limit switch tripping
P17
Intensity of stopping with closing
limit switch tripping
P18
Separate buttons
Settable values
ON/OFF
2-600 seconds
1= when opening, AP/CH input not active (condo)
2=AP/CH as sequential (open, stop, close, stop..)
3=AP/CH as sequential (open, open, close..)
ON/OFF
ON/OFF
1= photocell as protection on opening
(if engaged it stops the gate/barrier, until it is disengaged, and then it
continues in the same direction)
2= microswitch sensitive edge
3= resistive sensitive edge (balanced with resistance (8.2Kohm)
4= photocell as internal protection (if engaged it stops the gate/barrier,
until it is disengaged, then it continues opening)
1= disabled
2= flashes while the gate/barrier is moving
3= flashes while the gate/barrier is moving and stays on steady when
the gate/barrier is stationary
0= Control disabled, 1= Control on FOTO input
2= Control on STPA input, 3= Control on STPA and FOTO inputs
0-150cm
0-150cm
50-100%
50-100%
20-75% - Minimum speed 20%
20-75% - Minimum speed 20%
Min. 1-10 max
0-10
0= instantaneous stop
10= soft stop
0-10
0= instantaneous stop
10= soft stop
0= AP/CH controls complete opening and closing of the gate/barrier,
P
ED controls partial opening and closing of the gate/barrier
1= input AP/CH, controls opening only and input
PED, controls closing only
2= input AP/CH and the button of the remote control saved as CH1
controls opening only and the PED input and the button of the remote
control saved as CH2 controls closing only
EN
Press the button until you
see the parameter to be
modified
Default
Modified
value
value
ON
60 seconds
1
ON
OFF
1
2
0
73cm
49 cm
100%
100%
50%
50%
5
5
5
0
35