4.3.4 Calibration of the Speed Sensor
!
The calibration screen for the speed sensor is called by using the
data 1 screen.
Caution: The calibration must be carried out very precisely. This influences the speed,
the area measurement and the monitoring or control of the output quantity.
What to do:
1. Measure a 100m line on the field and mark it.
2. Drive the tractor with the machine empty to the marked line and set the machine in the operating position.
3. Press the
key in order to start the calibration process.
4. The key vanishes. The
5. Drive down the 100m line and stop at the end. While doing so, the number of pulses calculated are
displayed.
6. Press the
key at the end in order to confirm the calculated pulses.
The new value is displayed in the Machine Data screen 1. If the
calibration process is interrupted. The old value is retained.
Schéma 4-19a Calibration of speed sensor
and
keys appear.
Schéma 4-19b Calibrage capteur de vitesse suite
47
key in the Machine
key is pressed instead of
, the