Work Pro Digiline Serie Manual De Usuario página 19

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

You can see that the unit in the PROJECT INSPECTOR has a blue colour circle close to the name, it means that
both units are desynchronized.
Press on "ReSynch" button. It will appears to options: Device and Local, asking you which device is the correct one,
Device for physical device or Local for information present in the software.
Choose the desired option, the sotware will synchonize both device, loading the preset from our choice.
After this action, the point together the device in PROJECT INSPECTOR will change to green colour.
NOTE: This circumstance also occurs in the case of load a device from the library and setting it, creating
and saving presets. After, when you want to connect and load this information on a physical DIGILINE, both
devices will be different, therefore they need to be synchronized. In that case, the correct choice will be
Local.
3.3. GPI
DIGILINE devices incorporate GPIs (General Purpose Input), 12 GPI for DIGILINE MX.
Also, both devices incorporate LMI input. These inputs are contacts. We can assign to them commands to be executed
in both states: When the GPI is activated or deactivated.The LMI is a microphone analog input that, from the selected
threshold, allows to execute the assigned commands. LMI is very adequate as talkover.
GPI interface is accessible through GENERAL tab.
LMI setup
The Low and High level
must be set bettween 0 to
4000, When "0" means 0V
and "4000" means 3V.
Hysteresis cycle
When the input is greater than High
Level, the state pass to ON ACTIVATE.
When the input is less than Low
Level, the state pass to ON DEACTIVATE.
MX
MKII
PAGE 18

Publicidad

Tabla de contenido
loading

Productos relacionados para Work Pro Digiline Serie

Este manual también es adecuado para:

Digiline mx mkii

Tabla de contenido