9. Light Kit Assembly.
Remove 1 screw from motor plate on
underside of motor housing and partially
loosen the other 2 screws.
Connect WHITE wire from motor housing to
WHITE wire from light kit fitter. Connect BLACK
wire from motor housing to BLACK wire from
light kit fitter. Be sure molex connections snap
together securely.
Align slotted holes in light kit fitter with
loosened screws in motor plate. Twist light kit
fitter to lock. Re-insert screw that was
previously removed and securely tighten all 3
screws with Phillips screwdriver. [Note: It may
be necessary to use a short head screwdriver or
an offset screwdriver to securely tighten these
screws.]
Remove 2 screws from small posts located on
underside of center hole in light kit fitter. Raise
decorative cover to posts and align holes in
decorative cover with holes in posts. Attach
decorative cover with the 2 screws that were
just removed.
Install four 40 watt max. candelabra base bulbs
(included).
Important: When replacing bulbs, please allow
bulb(s) and light kit fitter to cool down before
touching them.
motor plate
screw
bulb
page 8
motor housing
motor plate
molex
connections
light kit fitter
decorative cover
post screw