ODOR FADE WARNING

WARNING
Asphyxiation Hazard
•­
Do­not­use­this­heater­for­heating­human­living­­
quarters.
•­
Do­not­use­in­unventilated­areas.
•­
The­flow­of­combustion­and­ventilation­air­must­­
not­be­obstructed.
•­
Proper­ventilation­air­must­be­provided­to­­ ­
support­the­combustion­air­requirements­of­the­­
heater­being­used.
•­
Refer­to­the­specification­section­of­the­heater's­­
manual,­heater­dataplate,­or­contact­the­factory­­
to­­determine­combustion­air­ventilation­­ ­
requirements­of­the­heater.
•­
Lack­of­proper­ventilation­air­will­lead­to­­ ­
improper­combustion.
•­
Improper­combustion­can­lead­to­carbon­­ ­
monoxide­poisoning­leading­to­serious­injury­or­­
death.­Symptom­of­carbon­monoxide­poisoning­­
can­include­headaches,­dizziness­and­difficulty­­
in­breathing.

FUEL GAS ODOR

LP gas and natural gas have man-made odorants added
specifically for detection of fuel gas leaks.
If a gas leak occurs you should be able to smell the fuel
gas. Since Propane (LP) is heavier than air you should smell
for the gas odor low to the floor. ANY GAS ODOR IS YOUR
SIGNAL TO GO INTO IMMEDIATE ACTION!
­ •­Do­not­take­any­action­that­could­ignite­the­fuel­gas.­Do­not­
operate­any­electrical­switches.­Do­not­pull­any­power­supply­
or­extension­cords.­Do­not­light­matches­or­any­other­source­
of­flame.­Do­not­use­your­telephone.
­ •­Get­everyone­out­of­the­building­and­away­from­the­area­
immediately.
­ •­Close­all­propane­(LP)­gas­tank­or­cylinder­fuel­supply­valves,­
or­the­main­fuel­supply­valve­located­at­the­meter­if­you­use­
natural­gas.
­ •­Propane­(LP)­gas­is­heavier­than­air­and­may­settle­in­low­
areas.­When­you­have­reason­to­suspect­a­propane­leak,­keep­
out­of­all­low­areas.
­ •­Use­your­neighbor's­phone­and­call­your­fuel­gas­supplier­and­
your­fire­department.­Do­not­re-enter­the­building­or­area.
­ •­Stay­out­of­the­building­and­away­from­the­area­until­declared­
safe­by­the­firefighters­and­your­fuel­gas­supplier.
­ •­FINALLY,­let­the­fuel­gas­service­person­and­the­firefighters­
check­for­escaped­gas.­Have­them­air­out­the­building­and­
area­before­you­return.­Properly­trained­service­people­must­
repair­any­leaks,­check­for­further­leakages,­and­then­relight­
the­appliance­for­you.
ODOR FADING - NO ODOR DETECTED
•­Some­people­cannot­smell­well.­Some­people­cannot­smell­
the­odor­of­the­man-made­chemical­added­to­propane­(LP)­or­
natural­gas.­You­must­determine­if­you­can­smell­the­odorant­
in­these­fuel­gases.
­ •­Learn­to­recognize­the­odor­of­propane­(LP)­gas­and­natural­
gas.­Local­propane­(LP)­gas­dealers­will­be­more­than­happy­
to­give­you­a­scratch­and­sniff­pamphlet.­Use­it­to­become­
familiar­with­the­fuel­gas­odor.
Mr. Heater | Gas-Fired Infra-Red Tank Top Heater
­ •­Smoking­can­decrease­your­ability­to­smell.­Being­around­an­
odor­for­a­period­of­time­can­affect­your­sensitivity­to­that­
particular­odor.­Odors­present­in­animal­confinement­buildings­
can­mask­fuel­gas­odor.
•­The odorant in propane (LP) gas and natural gas is
­
colorless and the intensity of its odor can fade under
some circumstances.
­ •­If­there­is­an­underground­leak,­the­movement­of­gas­through­
­
the­soil­can­filter­the­odorant.
­ •­Propane­(LP)­gas­odor­may­differ­in­intensity­at­different­levels.­
­
Since­Propane­(LP)­gas­is­heavier­than­air,­there­may­be­more­
­
odor­at­lower­levels.
• Always be sensitive to the slightest gas odor. If­you­
­
continue­to­detect­any­gas­odor,­no­matter­how­small,­treat­
­
it­as­a­serious­leak.­Immediately­go­into­action­as­discussed­
­
previously.
ATTENTION - CRITICAL POINTS TO
­
REMEMBER!
­
­ •­Propane­(LP)­gas­has­a­distinctive­odor.­Learn­to­recognize­
­
these­odors.­(Reference­Fuel­Gas­Odor­and­Odor­Fading­
­
sections­to­the­left­and­above).
­
­ •­Even­if­you­are­not­property­trained­in­the­service­and­repair­
of­the­heater,­ALWAYS­be­consciously­aware­of­the­odors­of­
propane­(LP)­gas­and­natural­gas.
­ •­If­you­have­not­been­properly­trained­in­repair­and­service­of­
propane­(LP)­gas­then­do­not­attempt­to­light­heater,­perform­
service­or­repairs,­or­make­any­adjustments­to­the­heater­on­
the­propane­(LP)­gas­fuel­system.
­ •­A­periodic­sniff­test­around­the­heater­or­at­the­heater's­
joints;­i.e.­hose,­connections,­etc.,­is­a­good­safety­practice­
under­any­conditions.­If­you­smell­even­a­small­amount­of­gas,­
CONTACT­YOUR­FUEL­GAS­SUPPLIER­IMMEDIATELY.­DO­NOT­
WAIT!

GENERAL INFORMATION

A.­­The­PAS15T­and­the­PAS30T­are­high­pressure­propane­
appliances­and­are­designed­to­be­connected­to­a­bulk­
propane­tank.­
B.­­These­heaters­are­equipped­with­an­automatic­Safety­Shutoff­
Valve.­The­gas­flow­will­automatically­stop­if­the­heater­fails­to­
operate­for­any­reason.­
C.­­Maximum­safety­and­convenience­have­been­built­into­the­
Hi-Med-Lo-Off­Control­Valve/Regulator.­The­following­table­lists­
the­approximate­BTU's­consumed­and­the­operating­hours­you­
can­reasonably­expect­from­bulk­propane­cylinders.­
D.­These­heaters­are­for­temporary­heating­of­buildings­under­
construction,­alterations,­or­repair.
Model
Valve Position
Hi
Med
Lo
Figure­3.
Actual BTU/HR input rate and fuel consumption times for this
appliance may vary.
4
Operating Instructions and Owner's Manual
PAS15T
PAS30T
BTU
Hours
BTU
Input
w/20lb.Tank
Input
15,000
28
30,000
12,000
36
24,000
10,000
43
10,000
Hours w/
20lb. Tank