English
ACCESSORY
WARNING
: Accessory other than these shown
below can lead to malfunction and
resulting injuries.
STANDARD ACCESSORY
Breather pipe plug ....................................1
Breather pipe ............................................1
APPLICATIONS
Air source of the pneumatic nailer and stapler.
WARNING
: Never
applications other than compressor
for pneumatic nailer and stapler.
PRIOR TO OPERATION
1.
Initial set-up
A) Read safety warnings before setting-up this
compressor.
B) Use a screwdriver or similar tool to remove the cap
on the lower part of the cylinder. (Fig. 2)
C) Ensure the oil level in this compressor pump is
adequate. If the oil level is low, replenish oil through
the fi lling hole so that the amount of oil will come
to the middle of the oil sight glass according to the
following OIL TYPE CHART.
OIL TYPE CHART
Ambient
50°F – 120°F
temperature
(10°C – 49°C)
Non-detergent oil
SAE15W40
multi-graded oil
for warm weather
use
compressor
Cylinder
Cap
Screwdriver
Hole of
crankcase
Fig. 2
-20°F – 120°F
(-29°C – 49°C)
SAE5W40
synthetic oil for
both summer and
use only
winter use
D) Insert the accessory breather pipe plug into the hole
of the crankcase.
Cylinder
Fig. 3
WARNING
WARNING
for
E) Insert the accessory Brether pipe into the air vent of
the Breather pipe plug and the hole of the air intake
fi lter. (Fig. 6)
— 8 —
Breather pipe plug
Fig. 4
: Drain tank to release air pressure
before removing the cap or the
breather pipe plug.
: Make sure air vent in breather
pipe plug is free from debris. If air
vent is blocked pressure can build
in crankcase causing damage to
compressor and possible personal
injury.
Fig. 5
Air intake fi lter
Cylinder
Breather pipe
Breather pipe plug
Fig. 6
Air vent
Air intake
fi lter
Hole