OperAting inStruCtiOnS
uSe Of the ChArger
Automatic charger / discharger for 4-10 cells nickel-cadmium and nickel-metalhydrid battery packs (4,8-12,0 V)
with a capacity of 500–5000 mAh (ACS 410p traveller 800-9.000 mAh).
feAtureS
> Microcontroller controlled charging
> Test phase at the beginning of the charging in order to recognize and indicate defect battery packs
> Short circuit detection and electronic protection against reversed battery
> Battery condition at the beginning of the charging is of no importance for the battery packs
> Supervision of the charging condition by a microcontroller during the whole charging time
> Safety stages like voltage gradient supervision and -delta U switch off as well as a safety timer are
integrated
> Possibility of discharging of the battery packs before use by pressing the button; after that, automatic
switching over to the charging
> Automatic switching over to trickle charge
> State indication through illuminated display
LeDS
Illuminated display red (1): the flashing of the red illuminated display can have different meanings:
1. It signs the perfect contact of the battery packs during the test phase (about 10 seconds).
2. It signs that the battery pack is not connected properly with regard to the pole
3. It signs the defect battery pack or unsuitable amount of cells
4. It signs the discharging after pressing the PRESS button
Permanent light signs the charging of the battery packs.
Illuminated display green (2): battery pack fully charged, trickle charge

OperAting eLementS

Discharging button (3): the discharging is started by pressing the PRESS button (for about two seconds).
AttentiOn
Only charge rechargeable Ni-Cd / Ni-MH battery packs. By using other batteries: Danger of explosion!