Substituting The Rubber And Teflon; Changing The Sealing Blade; Replacement Of The Supply Cord; Wiring Diagram - Minipack-Torre Galileo Manual De Usario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
Chapter 7. Ordinary maintenance

7.5. Substituting the rubber and Teflon

When the Teflon-strikers (32) are worn out, substitute them
with spare parts, making sure the application is linear and
even.
Before applying the Teflon self-adhesive strip clean the
rubber part (33) with a detergent.
If the rubber (33) is also damaged, substitute it as follows:
Remove the old rubber
Clean its housing
Insert the new rubber in a linear way
Clean the rubber with a detergent
Apply the self-adhesive Teflon-strip.

7.6. Changing the sealing blade

To replace the sealing blade (13) follow this procedure:
1.
Disconnect power to the machine
2.
Unscrew the 2 screws (V1) and remove the cover (21)
3.
Unscrew the screw (V2) intended to lock the sealing
blade in the piston (22)
4.
Remove the terminal (23) so as to extract the sealing
blade from the piston (22)
5.
Repeat the operations described by point 2-3-4 also
for the rear piston
6.
Unscrew the screw (V3)
7.
Remove the old sealing blade
8.
Clean the housing and if necessary replace the
insulating teflon (24) of the central clamp
9.
Insert the new sealing blade starting from the central
clamp and tighten the screw (V3)
10. Trim the new sealing blade according to the holes of
the pistons (22)
11. Complete the insertion if the sealing blade in the whole
housing
12. Push the front piston (22) completely onwards towards
the sealing blade to make it enter the hole of the piston
itself and then tighten screw (V2)
13. Repeat the operations described by point 12, also for
the rear piston
14. Trim the teflon projecting from the central clamp
15. Make sure that the sealing blade is well positioned and
in tension.

7.7. Replacement of the supply cord

ATTENTION!
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.

7.8. Wiring diagram

(page 93-94)
B1
Cycle start limit switch
B2
Rewinder limit switch
BT1
Thermocouple
E1
Cooling fan
ER1
Sealing blade heater
ER2/3 Heaters
FU1/2 Line fuse 10.3X38
FU3
Card supplier fuse 5X20
FU4/5 Fan fuse 5X20
FU6/7 Ventilator fuse, cooling pump, rewinder 5X20
FU8
Magnet fuse 5X20
G1
Cooling pump
K1
Electronic control board
M1
Fan motor
M2
Rewinder motor
Q1
Main switch
Q2
Rewinder switch
SK1
Control board
T1
Cutting transformer
U1
Shrinking magnet
U2
Sealing magnet
X1
Rewinder power supply socket
X2
Rewinder power supply plug
25
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Galaxy

Tabla de contenido