6. Commissioning, operation
6.3 Message structure
In the send message the transmission of the measured value, error detection and service requests are
combined. The D-1x-7 supports only DP-V0 and therefore a cyclic data exchange.
GB
Below, the encoding of the individual elements is clarified:
Send message
Byte 1
Byte 2
Pressure
Pressure
value MSB
value
with sign
LSB
Measured value
Measured value
Number format of the measured value: 16 bit integer (sign and magnitude representation)
Pressure value MSB (Byte 1): Bit 7 contains the algebraic sign
Pressure value LSB
Factor
Pressure value MSB (byte 1)
7
6
5
4
3
The representation is not carried out as a two's complement.
16
Byte 3
Byte 4
Factor,
Error status
Unit
Bit 6 ... 0 contains the highbyte of the measured value
(Byte 2): contains the lowbyte of the measured value
(Byte 3): contains the measurement type, unit and exponent
Pressure value LSB (byte 2)
2
1
0
7
6
5
WIKA operating instructions pressure transmitter model D-1x-7
Byte 5
Error code
Error detection
4
3
2
1
0
Pressure value
(Note the sign bit and factor)
Pressure value sign
0 = positive
1 = negative
Byte 6
Byte 7
Service
Service
request
response 1
Services
Byte 8
Service
response 2