WARNING: Remove the pump from its packa-
ging and carefully examine it. Do not discard the
packaging until all parts have been examined.
PUMP OPERATION
1. Assemble the Discharge spout onto the
pump head, using the threaded nut & washer
fitted onto the spout . Tighten the connection
by hand or lightly using a wrench.
2. Loosen the bung nut fitted onto the pump
tube & insert the pump into the drum.
3. Once the bottom of the pump touches the
base of the drum, securely fasten the bung
onto the drum.
4. Now very lightly tighten the bung onto the
pump tube. Note that excessive tightening
may damage the pump and render it in ope-
rational.
5. Take an empty container & place it below
the discharge spout. Start operating the pump
handle by moving it up by about 12" & then
4
down. Within a maximum of 4 strokes, pump
will be primed & will start dispensing media.
Amount of fluid discharge per stroke can be
controlled by the lift of the pump handle. The
5
more is the lift, greater will be discharge per
stroke. Never take the pump handle to its ex-
treme top position, but operate within a con-
venient lift height.
6. To prevent leaks, it is recommended that
the nut can loosen or tighten depending on
the viscosity of the media used to control any
media stream from this connection.
7. Once you have completed pumping the
media, it is a good practice to invert the dis-
charge spout upwards for a non-drip operation.
NOTE: If the pump is re used after an extended
period of time, it may loose it's prime & need
re-priming. Follow step 5 above.