BIP LD2-T_ _ _-03-S75
Inductive Positioning System
6
IO-Link interface (continued)
6.4
Identification parameters
Index
Parameters
Hex
Dec
0010 16
Vendor name
0011 17
Vendor text
0012 18
Product name
0013 19
Product ID
0014 20
Product text
0016 22
Hardware revision
0017 23
Firmware revision
0018 24
Application specific tag
Tab. 6-4:
IO-Link identification data
Access to subindex 0 addresses the entire
object of an index. Access of subindices >0
addresses the individual elements of an index.
Profile Characteristic
This parameter indicates which profile is supported by the
IO-Link device.
The inductive positioning system BIP supports the Smart-
Sensor profile with a process data variable:
–
Subindex 1 ("Profile Identifier -> DeviceProfileID"):
0x0001 ("Smart Sensor Profile")
–
Subindex 2 ("Profile Identifier -> FunctionClassID"):
0x8000 ("Device Identification Objects")
–
Subindex 3 ("Profile Identifier -> FunctionClassID"):
0x8002 ("ProcessDataVariable")
PD Input Descriptor
This parameter describes the composition of the process
data variables used.
The BIP inductive positioning system processes the
process variables (seeTab. 6-5 on page 13).
Application Specific Tag
The Application Specific Tag makes it possible to assign
the IO-Link device an arbitrary, 32-byte string. This can
only be used for application-specific identification and
applied in the parameter manager. The entire object is
accessed via subindex 0.
12
english
Data format (length)
StringT (7 bytes)
StringT (15 bytes)
StringT (19 bytes)
StringT (7 bytes)
StringT (28 bytes)
StringT (8 bytes)
StringT (8 bytes)
StringT (max. 32 bytes)
Access
Contents
Read only
"Balluff GmbH"
Read only
"innovating automation"
Read only
"BIP LD2-T103-03-S75"
Read only
"BIP 0014"
Read only
"Inductive Positioning System"
Read only
"v01"
Read only
"1.00.000"
Read/Write
"***"