Operation

WARNING: Do not handle this pump or plug in or unplug this pump with wet hands or while standing in water, unless you are certain all
power has been turned off to the pump. Remember, the pump should be connected only to a properly grounded, GFCI outlet.
1. Make certain the pump is submerged in water. Running the pump dry can damage the shaft seal.
2. Plug the pump cord into the back of the float switch cord's plug. Plug the float switch cord into a 115V GFCI power outlet.
3. After connecting power to the pump and periodically afterwards, test the pump:
a. Fill the basin to above the float switch operation on height. The pump should start pumping.
b. The pump should pump the water down to below its Float Switch Operation OFF Height and then stop pumping.
c. If the water drains back into the basin and restarts the pump, make sure the check valve is properly installed and working. Also make
sure that all pipe connections are tight.
4. The motor is equipped with an automatically resetting thermal overload protector. If the motor gets too hot, the overload protector will
shut off the pump before it is damaged. When the motor has cooled sufficiently, the overload protector will reset, and the motor will
restart.
NOTICE: If the overload protector stops the pump repeatedly, disconnect the power from the pump and check to find the problem. Low
voltage, a long extension cord, clogged impeller, screen blocked by debris, or water that is too hot can cause motor overheating.

Care and Cleaning

WARNING: Risk of electric shock. Can shock, burn or kill. Do not lift the pump by the power cord.
Before removing the pump from the basin for service, always disconnect electrical power to the pump and control switch.
Submerge the pump in a disinfectant solution (bleach) for at least one hour before disassembling the pump.
Unscrew the bolts (1), and remove the volute (5) and gasket (4).
Use a flathead screwdriver to hold the shaft (2), then turn the impeller (3) counterclockwise to release the impeller (3).
Remove debris from around the shaft (2) and on/under the impeller (3).
Reassemble the pump.