COMPARTMENT
DIMENSIONS FOR
BUILT-IN
INSTALLATIONS
ELECTRICAL
CONNECTION
8
When installing the unit inside a cabinet, you must
provide adequate space all around the device to
provide effective ventilation as well as a large
enough opening in the back that, in addition to
allowing the passage of the power cord and
inlet/outlet pipes, will also provide an adequate air
flow and the consequent optimum cooling of the
heat exchanger.
It is indispensable that the built-in compartment
have the following minimum dimensions shown in
the figure.
– Height
655 mm
– Width
660 mm
– Depth
700 mm
COMPARTMENT DIMENSIONS LESS THAN THOSE SHOWN MAY
COMPROMISE THE CORRECT CIRCULATION OF AIR AROUND THE
DEVICE AND MAY NOT PROVIDE ADEQUATE COOLING, WITH THE
CONSEQUENT DETERIORATION OF PERFORMANCE AND/OR
POSSIBLE DAMAGE.
DO NOT REMOVE THE UPPER COVER OR ANY OTHER EXTERNAL
PART. WHEN INSTALLED IN THE COMPARTMENT, THE DEVICE
MUST BE COMPLETE WITH ALL ITS PARTS.
P
LEASE REFER TO
TECHNICAL DATA
The sterilizer's must be connected to a socket of the electrical installation of adequate
capacity for the device's absorption, and ground provided, in conformity with current
laws and/or standards.
ARRANGE
DIFFERENTIAL BREAKER AND AUTOMATIC SWITCH
CONTACTS OPENING OF AT LEAST 3mm.
THE ELECTRICAL INSTALLATION MUST BE GROUNDED IN
COMPLIANCE WITH THE STANDING NORMS.
The differential and automatic breakers should have the following features:
– Nominal current I n
– Differential current I n
T
HE MANUFACTURER WILL NOT BE LIABLE IN CASE OF INSTALLATION OF THE
EQUIPMENT WITH INADEQUATE ELECTRICAL FACILITIES AND
.
GROUNDED
D
O NOT USE MAINS EXTENSIONS
THE
ELECTRICAL INSTALLATION SO THAT THE SWITCHES CAN BE EASILY
.
REACHED
WARNING
WARNING
NOTE
A
A (T
PPENDIX
ECHNICAL
.
WARNING
A
POWER
SUPPLY
16 A
0,03 A
NOTE
,
ADAPTORS OR OTHER ACCESSORIES