Safety Instructions - Helvi GLOBUS 175HF Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2.3 Safety instructions

For your safety, before connecting the source to the line, closely follow these instructions:
- an adequate two-pole switch must be inserted before the two-pole main outlet; this
switch must be equipped with time-delay fuses and it must match the data specified
in the chapter "Technical Specification";
- the mono-phase connection with ground must be made with a two-pole plug compatible
with the above mentioned socket;
- two wires of the two-pole input cable are used for the connection with the mono-
phase line and the yellow-green wire for the compulsory connection to the ground in
the welding location;
- connect all the metal parts which are near the operator in the welding location by
using cables bigger or of the same cross section of the welding cable to a ground
terminal;
- when working in a confined space, the power source must be kept outside the
welding area and the ground cable should be welded to the workpiece; do not work in
a damp or wet area in these conditions (Fig. 7).
FIG.7
- do not use damaged welding or input cables (Fig. 8);
FIG.8