8.5.2 Hilti injection anchor
Quality of concrete Normal armouring
subject to alterations!
Hilti injection anchor
concrete floor
type of dowel
drilling depth (mm)
min.anchorage depth (mm)
thickness of concrete (mm)
diameter of bore (mm)
thickness of the lift-piece (mm)
turníng moment (Nm)
Total length (mm)
Thread
piece number
It is possible to use equivalent injections dowels (with license) of other manufacturer but observe their
regulations.
100
without floor pavement (tiles)
HIT-V-5.8 M10x130
h
90
o
h
90
ef
H
min.120
min
d
12
0
t
max.17
fix
T
20
inst
I
130
M
10
a
b
c
d
e
f
g
Observe necessarily the installation description of the dowel ma-
nufacturer. Use longer dowels with version with floor pavement
OPI-POWER LIFT HF 3S 3000-4000 - HYMAX HF 3S 3000-4000 -V1.1-DE-EN-FR-ES-IT
POWER LIFT HF 3S 3000
d
POWER LIFT HF 3S 3500
d
POWER LIFT HF 3S 4000
e
HIT-V-5.8 M12x150
Art.Nr.387061
108
108
min.138
14
max.19
40
150
12
4
8
10
12
14
16
28
and tiles.
HIT-V-5.8 M16x200
Art.Nr.956437
144
144
min.180
18
23
80
200
16