Descargar Imprimir esta página

Mobile Installation; Fixed Installation; Electrical Connection - Olimpia splendid DOLCECLIMA compact 10 P Instrucciones Para La Instalación, Uso Y Mantenimiento

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 131

2.3 - MObILE INSTALLATION

the air conditioner must be installed in a suitable environment.
it is recommended to reduce solar radiation through curtains, Venetian blinds and to keep doors and windows
closed.
a. Position the air conditioner in front of a window or french window.
b. Position the machine side terminal (2) on the flexible hose (1) as shown by Fig.8.
c. Position the terminal (3) on the opposite side of the flexible hose (1) (Fig.8).
d. Insert the machine side terminal (2) on the air outlet grid of the appliance (26) as shown in figure 9.
e. Position the terminal (3) in such a way as to make air exit to the exterior (fig.10)
f. If you possess a sliding window (vertical or horizontal) or a shutter, it is possible to use the supplied
"SLIDER KIT" (4) which allows a more efficient installation.
For the installation with KIT SLIDER, proceed as shown in figures 11 and 12.
g. apply the adhesive seal (8) (fig.12)
h. Position the "Slider Kit" (4) and adapt it (fig.12)
i. Position the flexible hose (1) and apply the seal (9) (Fig.12)
Extend the pipe only to the necessary extent, so that the air conveyor remains closed between
the fixture shutters.

2.4 - FIXED INSTALLATION

The air conditioner can also be installed with fixed holes in windows or walls.
Air flow must not be obstructed by protective mesh or similar.
Any forms of protection must have a total cross-section for air flow of not less than 140 cm
a. Position the machine side terminal (2) on the flexible hose (1) as shown by Fig.8.
b. Drill a 127 mm hole in the glass or in the wall at a height above the floor included between 300 and 1200
mm (fig.13).
c. Position the terminal (6) in the wall hole and mark the drilling points.
d. remove the terminal (6) and drill 6 mm holes.
e. insert the supplied wallplugs (10) in the holes.
f. Position the terminal (6) in the hole of the wall and fix it with the supplied screws (10).
g. Insert the machine side terminal (2) on the air outlet grid of the appliance (26) as shown in figure 9.
h. Connect the other extremity of the flexible hose (1) on the terminal (6) (fig.14).
i. Insert the flange (7) in the terminal (6) and close the cap (7a) when the appliance is not running (fig.14).

2.5 - ELECTRICAL CONNECTION

The appliance is fitted with a power cable with plug.
Before connecting the air conditioner ensure that:
• The voltage and power frequency values match those specified on the
appliance plate data.
• The power line is equipped with an effective earth connection and is
correctly sized for maximum power consumption of the air conditioner.
.
2
EN - 19
DOLCECLIMA COMPACT

Hide quick links:

Publicidad

loading

Este manual también es adecuado para:

Dolceclima compact 8 pDolceclima compact 9 p01913