CI365 VACPAN™ INSTALLATION INSTRUCTIONS (
Refer to illustration at bottom of page.
IN WALL INSTALLATIONS
CI365 VACPAN can be installed between wall studs in side
•
walls.
CI365 VACPAN should be located tight to one side in stud
•
space.
Once the CI365 VACPAN location is determined, cut a
•
6¾" long x 1¾" high slot in the wall and baseboard to accept
the CI365 VACPAN.
The 2" x 4" wall bottom plate between the 2 studs must be
•
removed. This can be achieved from below using a hole saw.
In new home construction, the bottom wall plate can be
•
removed directly. A 6¾" length of 2 x 4 can be used as a
temporary rough in block, that will force all trades to finish
around, leaving a slot for the CI365 VACPAN.
Floor contractor must run flooring under block.
•
Run vacuum tube piping and low voltage wire from the main
•
line to CI365 VACPAN location.
Access for final piping connections must be made.
•
AH0007A
IN WALL INSTALLATIONS
CF382S
UNIVERSAL
SHORT 90° ELBOW
CI365 VACPAN™
A
B
CCESS FROM
ELOW
If access is available from below, cut an access hole through
the subfloor underneath the wall between the studs, positioned
so that final piping connections can be made by reaching
through the access hole.
A
W
CCESS THROUGH
ALL
Access can be made through the finished wall. Cut a
2¾" x 3½" access hole, positioned so that final piping
connections can be made by reaching through the access
hole. A generic cover plate can be used to cover the hole after
installation (sold separately).
Attach low voltage wires to CI365 VACPAN terminal
•
connections marked "low voltage only" .
Slide CI365 VACPAN into mounting slot and secure to toe
•
kick using two no. 6 screws provided.
Reach through access hole and make final fitting
•
connections.
COVER PLATE