Maintenance • Mantenimiento
Entretien • Manutenção
Fig. 1
Fig. 3
European waste disposal key / Código de residuos europeo
Code européen de déchet / Código europeu de dejectos
EWC 3005 (Mineral oil / aceites minerales / huile mineral / óleos minerais)
EWC 300 (Synthec oil / aceite sintético / huile synthetique / óleos sintéticos)
0
Fig. 1
Fig. 2
Fig. 4
Weekly waste water test
• Fill test tube at the sampling valve.
• Compare the cloudiness with the refer-
ence jar.
If the sample is clearer than the reference
cloudiness
• the filter is O.K. (Fig. 1)
If the sample is cloudier than the refer-
ence cloudiness
• the filter needs to be changed!
(Fig. 2)
NOTE: Never pour any foreign liquid
into the pressure relief chamber! This
Fig. 2
can impair the filter efficiency of the
ÖWAMAT.
Weekly checking of oil collector
• When the oil collector is ¾ full, it should
be replaced with another one.
• The collected oil must be disposed of
as waste oil:
Oil collector replacement:
1. Open the lid and push upwards to-
gether with discharge pipe.
2. Close and remove the filled oil col-
lector,
3. Place an empty collector underneath
the discharge pipe.
4. Push the discharge pipe downwards
and close the lid tightly.
Checking of level indicator
• Level indicator not visible:
- Filter condition of both stages is O.K.
• Red ring area visible:
- Main filter stage is clogged.
Replace OEKOSORB filter set!
The level indicator can be equipped with an
alarm contact as an option (page 32).
This contact switches reliably in the event
of a rising fill level inside the ÖWAMAT
unit.
• Excessive inflow quantity
• Filter clogged
• Water outlet not functioning correctly
Weekly check of leaks
• Container
• Connections
english
ÖWAMAT 12, 14, 15, 16