Switch on the machine (see chapter 5.2) and
push the motor casing forward up to the limit
stop.
Pull back the motor casing and switch off the
machine.

5.4 Drilling with stop pin

The base plate 22 (Fig. 5) is equipped with two
resilient stop pins. They are used to place the drill
holes at a fixed distance to the outer edge of the
workpiece. The machine stop can be positioned at
the left or right.
Clamp the workpiece or prevent it from moving
by using the anti-slip mats supplied.
Position the machine on the workpiece. At the
same time you push in a stop pin 20 and allow
the other stop pin to butt at the outer edge of the
workpiece.
With your free hand, press the tilting stop
against the workpiece.
Switch on the machine (see chapter 5.2) and
push the motor casing forward up to the limit
stop.
Pull back the motor casing and switch off the
machine.
7

Troubleshooting

Some of the most frequent defects and their causes are listed in the following chart. In case of other defects,
contact your dealer or the MAFELL customer service.
Defect
Machine cannot be switched on
Machine stops while drilling is in
process
Burn marks on the drill holes
Chip ejection blocked
Danger
Determining the causes for existing defects and eliminating these always
requires increased attention and caution. Pull the mains plug beforehand!
Cause
No mains voltage
Mains fuse defective
Carbon brushes worn
Mains failure
Blunt drill bit
Wood is too damp
Extended drilling without
extraction
-19-

5.5 Drilling with additional stop

see page 77
6

Service and maintenance

Danger
Pull the power plug during all
service work.
MAFELL machines are designed to be low in
maintenance.
The ball bearings used are greased for life. When the
machine has been in operation for a longer period of
time, we recommend to hand the machine in at an
authorised MAFELL customer service shop for
inspection.
Only use our special grease, order No. 049040 (1 kg
tin) for all greasing points.

6.1 Storage

If the machine is not used for a longer period of time,
it has to be carefully cleaned. Spray bright metal parts
with a rust inhibitor.
Elimination
Check power supply
Replace fuse
Take the machine to a MAFELL
customer service shop
Check mains back-up fuses
Regrind drill bit or replace
Connect to an external exhaustion,
e.g. portable dust extractor