Mitsubishi Electric CITY MULTI PLFY-P12NBMU-E Manual De Instrucciones página 7

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. Operation
< Process for setting >
[1] To turn off air conditioner and change the remote
controller to "Fixed airfl ow direction mode"
1.Press ON/OFF button
to turn off the air conditioner.
2.Press Fan Speed button
seconds simultaneously and it becomes the fixed airflow direction
mode after a while.
"Fixed airflow direction mode" display
Air blows downward after it becomes
"fixed airflow direction mode"
[2] To select and identify the outlet to set
1.Press Set Temperature button
blinking. Select outlet No. to set.
Up/Down air direction Address No. of indoor unit
Outlet No.
Outlet No.3
Outlet No.2
2.Press Filter
button
to send the information on remote controller.
3. Wait for 15 seconds . How does the air conditioner run?
Only the air from the selected outlet blows downward.
Go to step[3].
Air from the wrong outlet blows downward.
Repeat 1 and set again.
All outlets are closed.
The number of the air conditioner (Address No. of indoor unit) is
wrong. Refer to How to fi nd air conditioner No..
[3] To fi x air direction
1.Press Mode button (Return button)
indicater.
2.Press Set Temperature button
3.Press Filter
button
to send the information on remote controller to
air conditioner.
4.Wait for 15 seconds . How does the air conditioner run?
Airfl ow direction is set in the selected direction.
The fi xed setting is completed (Go to step [4].)
Airfl ow direction is set in the wrong direction.
Repeat 2. and set again.
Up/Down air direction
Outlet No.
Air direction changes
This indicates NO FIXED SETTING(canceled)
and Filter
button
for more than 2
to change number with the outlet No.
Outlet No.4
MITSUBISHI
ELECTRIC
label
Outlet No.1
Note: "0" indicates
all outlets.
to blink Up/Down air direction
until the direction to set is chosen.
Address No. of indoor unit
[4] To cancel "Fixed airfl ow direction mode"
1.Press ON/OFF button
to cancel "Fixed airfl ow direction mode".It is
also canceled by pressing Fan Speed button
for more than 2 seconds simultaneously.
2.Do not operate remote controller for 30 seconds after the "Fixed
airflowdirection mode" is canceled. It does not accept even if it is
operated.
and Filter
button
7

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido