Trouble Shooting; Assistance - KitchenAid 720-0787D Manual De Uso

Asador autónomo para exteriores
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Grill will not light
 Is the 20 lb LP gas fuel tank valve turned off?
Turn the 20 lb LP gas fuel tank on.
 Is the grill properly connected to the gas supply?
I th
ill
l
Contact a trained repair specialist or see Installation
Instructions.
 Is there gas in the 20 lb LP gas fuel tank?
Check the gas level.
 Is the igniter working?
Check that the igniter battery is properly installed or check
to see if the battery needs to be replaced. See the
"Replacing the Igniter Battery" section
Replacing the Igniter Battery section.
Check to see if the grill will match-light. See "Manually
Lighting the Main Grill" in the "Outdoor Grill Use" section.
Check for loose wire connections to the igniter or electrodes.
Check to see if debris is blocking the electrodes.
If a spark occurs anywhere but the igniter tip, replace the
igniter.
Burner flame will not stay lit
 Is the gas supply fully turned on?
Check that the 20 lb LP gas fuel tank valve is fully open.
 Is the gas supply in the 20 lb LP fuel gas tank low?
Check the gas level.
 Is the burner properly installed and in good condition?
I th b
l i
Check that the burner is installed properly. Check for defects
in the burner.
Flame is noisy, low or erratic
 Is the gas supply fully turned on?
Check that the 20 lb LP gas fuel tank valve is fully open.
 Is the gas supply in the 20 lb LP fuel gas tank low?
Ch
Check the gas level.
k th
l
l
 Does only one burner appear low?
Check and clean the burner ports if clogged or dirty. See
"General Cleaning" section.
 Is the gas supply hose bent or kinked?
Straighten the gas supply hose.
 Is the flame noisy or lifting away from the burner?
Burner may be getting too much air. Check the air shutter
adjustment, see Check and Adjust Burners section.
adjustment see "Check and Adjust Burners" section
 Is the burner flame mostly yellow or orange?
Grill may be in an area that is too windy, or not receiving
enough air. Check the burner air inlets for obstructions.
Check the air shutter adjustment, see "Check and Adjust
Burners" section.

TROUBLE SHOOTING

t d t th
l ?
t ll d
d i
d
diti
Excessive flare-ups
 Is there excessive fat in the food being grilled?
Keep flame on low or turn one burner off.
Keep the hood up when grilling to avoid excessive flare-ups.
K
th h
d
Move food to the warming rack until flames subside.
To avoid damage to the grill, do not spray water on gas
flames.
Low heat
LP Gas:
For outdoor grills using a 20lb LP gas fuel tank, slowly open
the tank valve.
NOTE: If flow limiting device activates, your grill may not light.
If your grill does light, the flames will be low and will not heat
properly.
1.
Turn tank valve and all control knobs off and wait 30
seconds.
2
2.
After shutting off the tank very slowly open the tank
After shutting off the tank, very slowly open the tank
valve and wait 5 seconds before lighting.
3.
Light the burners one at a time. See "Lighting the Main
Grill" section.
Natural Gas:
Gas pressure is affected by size and length of the gas line
from the house to the grill. Contact a qualified gas technician
to provide the Natural gas supply to the selected grill location
p
?
in accordance with the National Fuel Gas Code ANSI Z223.1/
NFPA54 - latest edition and local codes.

ASSISTANCE

Before calling for assistance, please check
Before calling for assistance, please check
"Troubleshooting." If you still need help, follow the
instructions below.
When calling, please know the purchase date and the
complete model and serial number of your appliance. This
information will help us to better respond to your request.
If you need replacement parts
If you have questions or need to order replacement parts,
contact Customer Service Center at 1-877-373-2301
Please direct all correspondence to:
Nexgrill Industries, Inc.
5270 Edison Avenue, Chino, CA 91710
Please include a daytime phone number in your
Please include a daytime phone number in your
correspondence.
Accessories
Natural Gas Conversion Kit
Order Part Number 710-0003
h
illi
t
id
g
pp y
i
fl
g
31

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

730-0787d