DORA
200 HT - 260 HT
4. IMPORTANT INFORMATION
4.1 Compliance with European regulations
This heat pump is a product intended for domestic use in com-
pliance with the following European directives:
• Directive 2012/19/EU (WEEE)
• Directive 2011/65/EU on the restriction of the use of certain
hazardous substances in electrical and electronic equipment
(RoHS)
• Directive 2014/30/EU electromagnetic compatibility (EMC)
• Directive 2014/35/EU low voltage (LVD)
• Directive 2009/125/EC eco-friendly design
• Directive 2014/53/EU radio equipment (RED)
• Regulation 2017/1369/EU energy labeling
4.2 Casing protection rating
The equipment protection rating is: IP24.
4.3 Operating limits
PROHIBITION! This product is not designed or
intended for use in hazardous environments
(due to the presence of potentially explosive
atmospheres - ATEX or with required IP level
higher than that of the unit) or in applications
requiring safety features (fault-tolerant, fail-safe)
which may be systems and/or technologies to
support life or any other context in which the
malfunction of an application can lead to death
or injury to people or animals, or serious dam-
age to property or the environment.
NB!: If the possibility of a product fault or failure can
cause damage (to people, animals and property) it is nec-
essary to provide for a separate functional surveillance
system equipped with alarm functions in order to exclude
such damage. It is also necessary to arrange the replace-
ment operation!
DORA is not designed for installation outdoors but in a
"closed" place not exposed to the elements.
4.4 Operating limits
The product in question is designed exclusively for heating hot
water for sanitary uses within the limits described below. For
this purpose, it must be connected to the domestic water sup-
ply and the power supply (see chapter "5. INSTALLATION AND
CONNECTIONS").
4.4.1 Temperature range
80
75
70
65
60
B
55
50
45
40
35
A = Inlet air temperature (°C)
B = Hot water temperature (°C)
= Operating range for heat pump (HP)
= Integration with heating element only
4.4.2 Water hardness
The unit must not operate with water of hardness under 12°F;
however, with particularly hard water (above 25°F), it is advis-
able to use a properly calibrated and monitored water softener,
in this case the residual hardness must not fall below 15°F.
NB! The manufacturer declines any liability for
uses different from those for which the equip-
ment is designed, and for any installation errors
or improper use of the unit.
PROHIBITION! Using the product for purposes
other than that specified is prohibited. Any other
use is deemed improper and not permitted.
NB!: In the design and construction phase of the plants,
the applicable local regulations and provisions must be
respected.
cod. 3541T630 - Rev. 03 - 05/2020
0
10
20
30
A
4°C
fig. 7 - Chart
75°C
62°C
38°C
40
50
43°C
73
EN