4.3.2 Electrohydraulic pump
3
DANGER
Servicing work on the electric system may only be done
by trained electricians.
When using an electrohydraulic pump
as the central pump for lifting and/
or lowering a load, it is imperative that
the operating manual of the pump be
observed.
> Connect the jack to the pump with the hose (1).
> Open the stop cock (2).
> Close the needle valve (3).
© JUNG Hebe- und Transporttechnik GmbH
> Plug the mains plug into a suitable socket. Check to
make sure the voltage and frequency are correct
> To activate the remote control of the pump, set the
rocker switch (5) to „ON".
Jacks of the JH / JH EX / JHS series
1
2
4
OFF
5
ON