5.5 Malfunctions and remedies
Fault
Load is not completely lifted
(lifting piston does not move out
completely)
Load is not lifted at all
Oil leak/oil film on pressure screw
or on venting valve with valve
closed
The specified errors do not constitute grounds for complaint.
- 64 -
Cause
Oil shortage
Permissible lifting force exceeded
Lowering screw open
Pressure screw loose
Valve seat of the lowering screw
leaky due to foreign objects/
particles
Valve dirty
Valve defective
Oil filling plug is defective, vacuum
in the tank
Slight overpressure in the pump
container due to unintentionally ac-
tuating the pump linkage or strong
sunlight exposure while in transport
condition (venting valve closed).
Jacks of the JH / JH EX / JHS series
Error remedy
Refill oil, paying attention to the
filling level.
Use an additional or a larger jack.
Close the lowering screw.
Tighten the pressure screw.
Press in valve seat again; carefully
close lowering screw multiple times.
Remove valve and clean.
Remove valve and replace.
Replace oil filling screw.
Briefly open the venting valve; do
not actuate the pump linkage when
valve is in transport condition. Wipe
off oil film with rag.
© JUNG Hebe- und Transporttechnik GmbH