Operating instructions SATAjet 1000 B (RP/HVLP)
Exchange Manometer SATA adam:
Remove the air micrometer after losening the lateral fixing screw with hexa-
gonal key size 2. Mount the digital pressure gauge instead of the standard
air micrometer
Make sure that the air micrometer fixing screw (pos. 9) is mounted
properly in the gun and well tightened. Connect the paint spray gun to
the air supply, pull the trigger and adjust the requested spray pressure
by turning.
4.4 Correct adjustment of the dynamic inlet pressure
a) Spray gun with SATA adam (additional):
Adjust the required pressure of 1,5 - 2,0 bar/21.8 - 29 psi by turning at the
SATA adam of the spray gun. The pressure can exactly be adjusted with a
precision of indication of +/- 0,05 bar (+/- 1 psi) and can be permanently
controlled during the paint application.
b) Spray gun with micrometer / gauge
Ensure sufficient pressure by means of the pressure regulator. Adjust the
recommended inlet pressure of 1,5 - 2,0 bar/21.8 - 29 psi at the micrometer.
Art. No. 27771
c) Spray gun equipped with compressed air control gauge
Adjust the pressure at the pressure regulator in a way that the spray gun
inlet pressure required for the respective gun model is obtained.
Art. No. 4002
d) Spray gun without gauge
In order to make a correct adjustment of the spray gun inlet pressure, as
otherwise measureable in a) to c), without a gauge, adjust a pressure of
about 9 psi higher per 10 m to inlet pressure to compensate the pressure
drop in the hose.
4.5 Material flow control
Adjust material flow control
in accordance with spray viscosity and required flow rate (arrow 1 ) and fix
by means of the counter nut (arrow 2 ). Under normal circumstances, the
material flow control is fully open.
4.6 Round/flat spray control
Round/flat spray control for right-handed painters
for infinitely variable adaptation of the spray fan to the object:
Turn to the left - flat spray
Turn to the right - round spray
VIII.4
2
1