Battery notices
The device associated with this operating manual contains 2
AAA Alkaline batteries (1.5 V) in delivery condition. These bat-
teries are not made for recharging. The use of a rechargeable
battery is not possible with this device and can damage it. If
the included batteries are depleted, they must not be thrown
into the household waste. Used batteries may contain harmful
substances that can cause environmental or health damage.
Please return all depleted batteries to electrical appliance
stores, who collect them for free.
Battery exchange
To replace the batteries, push the battery cover on the rear of
the unit downwards and replace the discharged batteries with
new ones. Be aware of the polarity when inserting the batteries
(+/- pole). Close the battery compartment cover again. In the
EU the return of used batteries is mandatory by law. All deple-
ted batteries and also rechargeable batteries will be recycled.
This way valuable resources like iron, zinc and nickel can be
retrieved and are reusable then. Battery recycling is the easiest
lesson in environmental protection – so please support it!
The shown garbage bins mean that batteries or rechargeable
batteries must not be thrown into the household waste. The
signs below the garbage bins are acronyms for the chemical
substances inside the battery:
Hg: Battery contains Mercury
Cd: Battery contains Cadmium
Pb: Battery contains Lead
21
Technical data*
Sensor
Fuel Cell sensor
Accuracy
+/- 0.05‰ (per mill) with reference to 0.50‰
at 25°C (per mill = default setting)
OR +/- 0.005% BAC (Blood Alcohol Concentra-
tion) with reference to 0.05% BAC at 25°C
OR +/- 0.025mg/L with reference to 0.25mg/L
at 25°C
Detection
0.00 up to 4.00‰ (per mill)
range
OR 0.00 up to 0.40% BAC (USA)
OR 0.00 up to 2.00mg/L (UK)
Warm-up
Within 3 seconds up to max. 4 minutes – at
time
0.5‰, it may vary depending on the value
of per mill (g/L) or mg/L or BAC which was
measured.
Dimension
100 x 44 x 15mm (L x W x H)
Weight
66g (battery included)
Power
2 pieces of 1.5V AAA Alkaline batteries (=
supply
energy for up to 400 tests)
Working
5°C up to 40°C
temperature
Storage
0°C up to 50°C
temperature
Calibration
Every 12 months or after 1000 tests. For a
calibration service you can send the device
to ACE Instruments (see www.alkomat.net).
* The technical data are subject to change without prior notice
for functional improvements.