Maintenance; Decommissioning; Warranty; Troubleshooting - Schneider Airsystems FSP-Optimal 2001-1,5 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
GB
FSP
After use:
1. Disconnect the quick-action coupling
from
the
plug
(Figure 1b).
2. Clean the housing immediately using
suitable cleaning agents.
3. Do not use any organic halogen solvents,
tricholoromethyl, ethylene chloride etc.
4. Do not immerse completely in cleaning
bath /
machines.
Replacing the nozzle set:
1. Paint spray gun without pressure and
cleaned.
2. Unscrew the paint quantity regulation
(item 03) and pull out the nozzle needle
after
actuating
(item 02) (Figure 3a)
3. Depending on the type of the paint spray
gun.
Remove the air cap (item 11), slotted
nozzle (item 13),
or union nut (item 06)
(see Figure 3a).
4. Remove the material cap using a suitable
key (Figure 3b).
5. Install the new nozzle set in reverse se-
quence.
Nozzle sets are wear parts; keep a spare
ready. When replacing, always replace
the entire nozzle set (Figure 3c).

2.8 Troubleshooting

Problem
A
The paint spray is
interrupted or
pulses
II/8
nipple
(item 01)
the
trigger
lever
Cause
Hold the gun at an incline
Material cap is loose or dam-
aged
Viscosity is too high
Ventilation in cover or drip
guard (item 09 or 14) is
clogged

2.5 Maintenance

Apply a light coat of oil to the valve pin.
Do not use any materials containing silicon
for cleaning or lubrication.

2.6 Decommissioning

Storage: Clean, dry, dust-free, not below
5° C.
Store paints / solvents according to applica-
ble legal provisions.
Disposal: Dispose of the packaging / device
/ materials used according to applicable legal
regulations.

2.7 Warranty

Basic principle: complete unit in original
condition / proof of purchase.
Material and production defects are covered
by statutory provisions.
Excluded warranty claims: Wear or ex-
pendable parts, improper use, overloading /
incorrect pressure, manipulation / inappro-
priate use, inadequate / incorrect / lack of
maintenance or lubrication, bumps / im-
pacts, dust / dirt accumulation, unauthorised
/ incorrect working procedures, incorrect
power supply, impure / insufficiently filtered
compressed air, failure to read the instruc-
tion manual, incorrect operating resources /
materials.
Remedy
Guide the gun such that the vessel
is vertical
Screw the material cap tight or re-
place the entire nozzle set (see
Figure 3a-c)
Decrease viscosity, use nozzle set
with larger diameter, correct vis-
cosity
****
Clean
***

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

D030059

Tabla de contenido