SOLUTION FILTER CLEANING
1.
Empty the solution tank (32) as shown in the relevant paragraph.
2.
Drive the machine on a level fl oor.
3.
Make sure that the switches (65 and 66) are turned to "0".
4.
Remove the transparent cover (A, Fig. 8) and the fi lter strainer (B); clean and reinstall them on the support (C).
NOTE
The fi lter strainer (B) must be correctly positioned on the housing (D) of the support (C).
MACHINE SPEED ADJUSTMENT
NOTE
The machine speed varies according to the type of fl oor to be cleaned and the choice of using the brush or the pad.
The machine speed can be adjusted according to the following procedure.
1.
Remove the recovery tank as shown in the Use chapter.
2.
Adjust the machine speed with the screw (53) according to the following procedure:
•
Loosen the screw (57), on the right side of the machine, by turning it counter-clockwise.
•
Turn the adjusting screw (53) counter-clockwise to increase the machine speed.
•
Turn the adjusting screw (53) clockwise to decrease the machine speed.
•
After adjusting, tighten the screw (57).
3.
Install the recovery tank as shown in the Use chapter.
4.
With the machine ready to operate, perform hands-on tests of the machine and, if other adjustments are necessary, repeat
steps 1 to 4.