Wavetek Meterman AC68 Manual De Instrucciones página 18

Tabla de contenido

Publicidad

AC Current
Range
Resolution Accuracy
400A
0.1A
600A
1A
DC Voltage
Range
Resolution Accuracy
600V
1V
AC Voltage – Frequency response: 40-450Hz
Range
Resolution Accuracy
400V
0.1V
600V
1V
Frequency (Hz) – Autoranging for current and voltage
Range
Resolution Accuracy
4KHz
0.001Hz
20KHz
0.01Hz
Resistance
Range
Resolution Accuracy
4KΩ
1Ω
Diode Test
Range
Resolution Accuracy
0.001V
Max short circuit current: 0.8mA (typical)
Audible Continuity Test
Range
Threshold
40Ω ±15Ω 3.2VDC max
Max short circuit current: 0.8mA (typical)
Peak Hold Measurement, AC Voltage
Range
Resolution Accuracy
400V
0.1V
600V
1V
Frequency response: 40-450Hz
Peak Hold Measurement, AC Current
Range
Resolution Accuracy
400A
0.1A
600A
1A
D • Spezifikationen
Allgemeine Spezifikationen
Anzeige: 3 3/4-stelliges LCD, max Ablesung 3999. Funktions- und
Einheitsanzeigen
Überlastanzeige : "OL".
Polaritätsanzeige: automatisch; positiv unterstellt; negativ angezeigt.
Nullabgleich: automatisch für alle Funktionen und Bereiche, ausg. Gleichstrom
(Nullabgleichtaste).
±(2%rdg + 5dgt)
±(2%rdg + 5dgt)
±(0.75%rdg + 2dgt) 10MΩ
±(1.2%rdg + 5dgt) 10MΩ
±(1.2%rdg + 5dgt) 10MΩ
±(0.5%rdg + 5dgt) 5A/1V
±(0.5%rdg + 5dgt) 5A/5V
±(1%rdg + 5dgt)
±(1%rdg + 2dgt)
Open circ.volts
±(1.5%rdg +10dgt) 10MΩ
±(1.5%rdg +10dgt) 10MΩ
±(2%rdg +10dgt)
±(2%rdg +10dgt)
– 16 –
Overload Prot.
800A
800A
Input Imped. Overload Prot.
1000VDC/750VAC
Input Imped. Overload Prot.
1000VDC/750VAC
1000VDC/750VAC
Sensitivity Overload Prot.
660Vrms/800A
660Vrms/800A
Open circ.volts Overload Prot.
0.5VDC
660Vrms
Open circ.volts Overload Prot.
3.2VDC max
660Vrms
Overload Prot.
660Vrms
Input Imped. Overload Prot.
1000VDC/750VAC
1000VDC/750VAC
Overload Prot. Freq. Response
800A
40-450Hz
800A
40-450Hz
Freq. Response
40-450Hz
40-450Hz

Publicidad

Tabla de contenido
loading

Tabla de contenido