Kenmore 11072812101 Instrucciones De Instalación página 6

Secadora a gas de 29 pulg. (73,7cm)
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

The dryer exhaust must not be connected into any gas vent,
Standard
exhaust installation with rigid metal or flexible
chimney, wall, ceiling, or a concealed space of a building,
metal vent
Do not use an exhaust hood with a magnetic latch.
Do not install flexible metal vent in enclosed walls, ceilings or
floors.
Use clamps to seal all joints. Exhaust vent must not be
connected or secured with screws or other fastening devices
which extend into the interior of the duct. Do not use duct
tape.
IMPORTANT: Observe all governing codes and ordinances.
Improper
venting can cause moisture and lint to collect
indoors, which may result in:
Moisture damage to woodwork,
furniture, paint, wall-
paper, carpets, etc.
Housecleaning
problems and health problems.
Use a heavy metal vent. Do not use plastic or metal foil vent.
Rigid metal vent is recommended
to prevent crushing and kinking.
Flexible metal vent must be fully extended and supported
when
the dryer is in its final position. Remove excess flexible metal vent
to avoid sagging and kinking that may result in reduced airflow
and poor performance.
An exhaust hood should cap the vent to prevent rodents and
insects from entering the home.
Exhaust hood must be at least 12 in. (30.5 cm) from the ground or
any object that may be in the path of the exhaust (such as
flowers, rocks or bushes, etc.).
If using an existing vent system, clean lint from the entire length
of the system and make sure exhaust hood is not plugged with
lint. Replace any plastic or metal foil vent with rigid metal or
flexible metal vent.
Typical exhaust installations
Typical installations vent the dryer from the rear of the dryer.
/--
2
f
I
3
_ 2.,#¸,4
1. Dryer
2. Elbow
3. Waft
4. Exhaust hood
5. Clamps
& Rigid metal or flexible metal vent
7. Vent length necessary to connect
elbows
8. Exhaust outlet
Alternate
installations for close clearances
Venting systems come in many varieties. Select the type best for
your installation. Two close-clearance
installations are shown.
Refer to the manufacturer's
instructions.
-..L......
1
2
1. Over-The-Topinstallation (alsoavailable with one
offset elbow)
2. Periscope installation
NOTE: The following kits for close clearance alternate
installations are available for purchase. For further information,
please call 1-800-4-MY-HOME
_ (1-800-469-4663).
Over-The-Top Installation:
Part Number 26-49900
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 26-49901 - Less than 5 in. (12.7 cm) mismatch
Part Number 26-49908 - 5 in. (12.7 cm) to 18 in. (45.72 cm)
mismatch
Part Number 26-49904 - 18 in. (45.72 cm) to 29 in. (73.66 cm)
mismatch
Part Number 26-49905 - 29 in. (73.66 cm) to 50 in. (127 cm)
mismatch
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
6

Publicidad

Tabla de contenido
loading

Tabla de contenido