5
REGULAR MAINTENANCE
5.1 FLEXIBLE SHAFT AND WATER PUMP
1.
To do the maintenance works in the transmission and water pump, firstly disconnect from the
engine.
2.
In all maintenance operations, original parts must be used.
3.
A way to lubricate the shaft is to grasp some grease in the palm of the hand and run the close hand
with the lubricant over the length of the shaft, leaving on the shaft a light coating of the lubricant on
the entire length of the shaft, the recommended quantity is 25 g per metre. do not overlubricate, it
could cause the grease penetrates into the pump, or overforces the engine. do not clean the flexible
shaft with solvent. ask the manufacturer the type of grease that must be used.
4.
5.
6.
5.2 STORAGE
When the water pump has not been used for long periods of time, it should always be stored in
clean, dry, and protected area.
5.3 TRANSPORTATION
When transporting by vehicles, ensure the water pump is safe against slipping, overturning and
blows
6
LOCATING MALFUNCTIONS
6.1 DRIVE-PETROL ENGINE
PROBLEM
The motor doesn't work................................ 1.Check the gas level
The motor works slowly............................... 1.Water pump or inner core is damaged
VOLGA IMMERSION PUMPS
Lubricate the shaft every 100 working hours.
To do a maintenance follow the following steps:
-
Flush the parts with solvent and wipe all part.
-
Examine bearings and seals. If inspection reveals that grease of transmission has
penetrated into the water pump, the oil seals need replacement.
After maintenance job and service, all the parts must be assembled correctly.
Every 12 months or more frequently, depending on the usage conditions. It is recommended
an inspection be done by an authorized dealer.
PUMP UNIT 3" + FLEXIBLE SHAFT 6m VOLGA
CAUSE / SOLUTION
2.Check the gas admission key is open
3.Check the choke position
en
7