US
No. 48173), insert them together with the air piston and thighten the
locking screw [10-1]. Adjust material flow according to chapter 7.2 after
installation.
• Check if locking screw has been firmly tightened! Air micrometer could
shoot out from the spray gun uncontrolled!
9.5. Replacing the Sealing (air side)
• Disconnect the spray gun from the compressed air circuit!
Steps: [9-1], [9-2], [10-1], [10-2], [10-3], [10-4], [10-5] and [10-6]
Replacing the self-adjusting sealing [10-6] is required when air leaks
from under the trigger.
1. After disassembly, please check air piston rod [10-4] and clean it, if
required. If damaged (e.g. if scratched or bent), replace it and grease
with SATA high performance spray gun grease (Art. No. 48173) and
insert. Please observe correct order of installation!
2. Lubricate air micrometer (air flow control) and spring as well, insert
together with air piston and tighten the locking screw.
After installation, please adjust material flow according to chapter 7.2.
• Check if locking screw has been firmly tightened! Air micrometer could
shoot out from the spray gun uncontrolled!
9.6. Replace spindle of round/flat spray control
steps: [11-1], [11-2], [11-3]
The spindle has to be replaced when air leaks from the spray control or
when the spray control does not work.