Use only original spare parts and accessories. The use of other
parts will result in voiding the warranty and the CE marking, and
could cause injury.
The filter head must be replaced after 5 years.
Compliance statement (part 15.19)
This device complies with part 15 of the FCC Rules and with
Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may
cause undesired operation.
Warning (part 15.21)
Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to
operate the equipment.
RF Exposure (OET Bulletin 65)
To comply with FCC RF exposure requirements for mobile
transmitting devices, this transmitter should only be used or
installed at locations where there is at least 7 7/8'' (20cm)
separation distance between the antenna and all persons.
Information to the User (Part 15.105 (b))
Note: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for
help.
Technical data cooler/carbonator electrical data:
• Connection:
• Voltage supply:
• Max. power consumption:
• Type of protection:
• Relative air humidity:
• Refrigerant:
• Safety shut-off of pump:
• Operating pressure:
• Max. CO
inlet pressure:
2
• Max. refrigerant pressure:
• WLAN:
• Bluetooth:
• Temperature class:
Sanitary data:
• Cooler/carbonator cooled water capacity:
• Operating pressure:
• Flow rate at 43.5 psi flow pressure:
• Ambient temperature:
• Temperature
– Cooler/carbonator water inlet:
– Cooled water temperature:
• Sound pressure level LpA (frestanding):
• Adjustable bypass, factory setting:
• Water connection
– Cooler/carbonator:
19
Wall socket with earth wire,
protected via a 10 A fuse
110 V AC / 60 Hz
240 W
IP 21
max. 80%
0.070 kg - R134a
approx. 4:30 min
min. 29 psi- max. 145 psi
69.6 psi
435.1 psi
2.4 GHz, IEEE 802.11 b/g/n/e/i
v4.2 BLE
0.4 gal
max. 87 psi
approx. 0.5 gpm
39 °F – 95 °F
max. 75 °F
approx. 41 °F – 50 °F
50 ± 4 dB
cold - blue
Electrical test data:
• Software class:
• Contamination class:
• Rated surge voltage:
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
Technical data fitting:
• Flow pressure:
• Operating pressure:
• Test pressure:
To comply with noise levels if static pressure exceeds 72.5 psi, a
pressure reducing valve must be fitted.
Avoid major pressure differences between hot and cold water
supply.
• Flow rate at 43.5 psi flow pressure:
• Temperature
– Hot water inlet:
– Recommended (energy saving):
Water connection:
Thermical disinfektion of the fitting is possible.
GROHE ONDUS app and connection to the internet
A GROHE Blue cooler connected to the internet via Wi-Fi can be
integrated and configured in the GROHE ONDUS app. This app
can be used to deliver messages in the form of push notifications.
A WLAN router with internet access
(2.4 GHz, IEEE 802.11b/g/n) is required.
Only WLAN channels 1 – 11 can be used.
Installation of the app:
Apple:
Android:
If the app or the device firmware requires updating, the smartphone
must be located in the immediate vicinity of the GROHE Blue
cooler. In this way, possible interruptions in function can be
controlled and rectified.
Operating conditions
Interference sources
The transmitter/receiver unit operates in the ISM frequency band
(2.4 GHz). Installation in proximity to devices with the same
frequency band (e.g. WLAN devices, HF components, etc.
[observe manufacturer documentation!]) should be avoided.
Obstructions/barriers
Wireless reception can be impaired and interrupted under
unfavourable surrounding conditions, in buildings/rooms with
reinforced concrete walls, steel and iron frames or in proximity to
obstacles (e.g. furniture) made of metal. Where necessary, a
WLAN repeater must be connected to the main router in order to
increase the range of the radio signal.
N
Installation and commissioning
GROHE recommends a depth of min. 19.7" for the
cabinet.
Flush pipes thoroughly before and after installation
(observe EN 806)!
Adjust bypass of filterhead according to local carbonate
hardness and connect filter cartridge.
The carbonate hardness can be tested by using the enclosed test
2
strip or the relevant water supplier can provide information on the
carbonate hardness.
A
2
2,500 V
29 – 130.5 psi
max. 14.5 psi
232 psi
approx. 1.8 gpm
max. 158 °F
140 °F
cold - right
hot - left