Operating instructions SATA air humidifier
EN
The air humidifier is an optional addition to the breathing protection appa-
ratus and is used to provide moistened breathing air.
4. Description
The air humidifier is an optional part of the breathing protection appara-
tus. It moistens the breathing air and is fitted between the air regulator
and the breathing protection hood. It consists of the main parts:
■ Connection for breathing protection hood (rotating) [2-1]
■ Connection for air regulator (rotating) [2-6]
■ Water tank [2-4] with humidifier module [2-5]
■ CCS disk [2-10] to personalise the air humidifier
5. Scope of Delivery
■ SATA air humidifier
■ CCS-disks, 1 bag (red, black, green, blue), red is mounted
6. Technical Design
Connection for breathing
[2-1]
protection hood (rotating)
Filler screw
[2-2]
Pressure relief valve
[2-3]
[2-4]
Water tank
[2-5]
Humidifier module
[2-6]
Connection hose for air
7. Technical Data
Description
Max. operating overpressure (at air
humidifier input)
Operating temperature
Storage temperature
Noise level (2.5 bar, air regulator
completely closed)
Noise level (6 bar, air regulator
completely open)
Weight air humidifier (not filled)
8. First Use
80
regulator with anti-kink
protection (rotating)
Cover
[2-7]
SATA filter timer
[2-8]
[2-9]
Lid
[2-10] CCS-disk
[2-11] Adapter plate
Unit
2,2 bar
+5 °C – +60 °C
-20 °C – +60 °C
65 dB (A)
79 dB (A)
462 g