"Water" comfort climate
When the water temperature set by the user is reached, the stove switches to "Modula Work". If the water temperature increases by
a COMFORT CLIMATE DELTA (preset) keeping this temperature for a predetermined period of time, the thermo-stove automatically
switches to ECO STOP (the thermo-stove goes off).
OFF
PR42
COMFORT
CLIMATE
10°
PR42
COMFORT
CLIMATE
10:30
21°
WORK
MODULA
10:34
21°
ECO
STOP
Please note: Operation of the thermo-stove in WATER CLIMATE COMFORT mode can start the ignition and shutdown phase several
times throughout the day; this can adversely affect the resistance duration of the automatic thermo-stove switch-on.
! IMPORTANT
"STAND-BY" mode
STAND-BY mode is activated when the water temperature reaches 85°C; this function is triggered to protect the circuit, especially
when no COMFORT CLIMATE function is active for water. If the thermo-stove is in this condition, it automatically switches to STAND-
BY mode to ensure hydraulic circuit protection.
The stove will automatically restart after cooling provided it is required to operate (room temperature is lower than the
required room temperature setting).
Changing the room temperature set point
The operating modes of the thermo-stove with an active room thermostat are divided into 2 types:
- with a room sensor on the back of the stove provided as standard;
- with an external thermostat (not provided as standard);
Model Rodi Steel Use and Maintenance Manual
51°
51°
WHEN THIS MODE IS USED, MAKE SURE THAT AFTER ANY AUTOMATIC SWITCH-OFF THE
BRAZIER IS ALWAYS WELL CLEANED SO AS TO ENSURE PROPER AUTOMATIC SWITCH-ON.
COMFORT CLIMATE MODE IS ACTIVE EVEN WITH A CONNECTED EXTERNAL THERMOSTAT.
To activate Comfort Climate, after simultaneously pressing P4 and P6,
press the P5 key to set a value other than OFF.
The set value ( in this case 10°C ) has activated the Comfort Climate
function.
OPERATION:
The value adjusts the thermo-stove restart temperature.
EXAMPLE:
• Water temperature value set to 51°C
• comfort climate value set to 10° C
With this setting, the thermo-stove switches off when it reaches 61°C and
switches back on when the following conditions are met:
- The water temperature is about 40°C (51°C -10 -0.5 of tolerance = about
40°C)
- The room temperature is not reached
The following strings appear sequentially on the display:
Modulation phase is activated, as the water temperature set point has
been reached. If the temperature reaches the "water set point"+ "delta-
comfort climate" and is maintained for a few minutes, the thermo-stove
switches off.
Once the switch-off phase is over, the display will show ECO STOP. The
thermo-stove remains in this mode until the temperature drops to 40°C
and there is a heat request in the room; only then will the switch-on phase
restart.
10:34
21°
86°
WATER
STAND-BY
Rev.2 31/07/2017
Page69