Operating Instructions SATAjet 5000 B RP/HVLP PHASER
EN
Check sealing surfaces inside the spray gun [8-2] after disassembly,
clean them, if required. Should the sealing surfaces be damaged,
please contact your SATA dealer. Align new air distribution ring with the
help of the marking [8-3], (pin must be located in the drilling) and press
in with even force. Adjust material flow according to chapter 7.2 after
installation.
9.3. Replacing the paint needle sealing
[9-2] und [9-3]
This must be replaced when material leaks from the self-adjusting paint
needle packing. Remove trigger guard after [9-2]. Check paint needle for
any signs of damage, replace nozzle set if necessary. Before removing
the trigger guard [9-2], the air micrometer has to be dismantled [10-1] –
[10-4]. After installation, adjust the material flow according to chapter 7.2.
9.4. Replacing the air piston, air piston spring and
air micrometer
• Disconnect spray gun from the compressed air circuit!
This must be exchanged if air is leaking from the air nozzle or the air
micrometer while the trigger is not pulled. After disassembly, grease air
micrometer shell with SATA gun lubricant (item no. 48173), insert with
air piston and tighten locking screw using original SATA combination tool
with max. 1 Nm. [10-1]. After installation, set material throughput accord-
ing to chapter 7.2.
• Check if locking screw has been firmly tightened! Air micrometer could
shoot out from the spray gun uncontrolled!
112
Notice!
Steps: [10-1], [10-2] and [10-3]
Warning!
Warning!
Steps: [9-1],