Electrical Wiring - Electrolux EN19WI30LS Manual De Instalación

Ocultar thumbs Ver también para EN19WI30LS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

13.

Electrical Wiring

Do not connect electrical power to the unit until all electrical wiring has been completed.
Disconnect Power
This appliance must be electrically grounded in accordance with local codes, or in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70.
Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation.
Verify proper operation after servicing.
Field wiring to be performed at time of appliance installation.
Electrical Shock Hazard
Do not turn power on until electrical wiring is nished. Disconnect power before servicing.
Failure to do so may result in death or serious injury from electrical shock.
120VAC at 60 Hz.
The power consumption may be up to 306W or higher if
using optional accessories.
Use an appropriate circuit.
the power is off, the freeze prevention in the water heater
will not activate, resulting in possible freezing damage.
Ground
should do this work.
Do not connect the ground to the city water or gas piping. Do not tie the ground to a telephone line.
Breaker Installation
leakage is detected.
Electrostatic discharge can affect electronic components. Take precautions to prevent
electrostatic discharges from personnel or hand tools during the water heater installation and
servicing to protect product's electronic control.
30
WARNING
CAUTION
Consult a quali ed electrician
for the electrical work.
the gas piping.
Tie the redundant power cord
outside the water heater. Putting the
redundant length of cord inside the
water heater may cause electrical
interference and faulty operation.