Disposal; After Sales Service; Warranty / Liability - SATA minijet 3000 B HVLP Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 115
Operating Instructions SATAminijet 3000 B HVLP, minijet 3000 B T HVLP
EN
Malfunction
Corrosion on air cap
thread, inside material
passages (cup con-
nection) or on spray
gun body
Material leaks from
behind the paint nee-
dle sealing
Spray gun leaks from
the fluid tip ("fluid tip
aperture")

11. Disposal

Recycle the completely empty spray gun. To protect the environment, bat-
teries and residual paint have to be disposed in an appropriate way and
separately from the spray gun. Please observe local legislation!

12. After Sales Service

For accessories, spare parts and technical support, contact your SATA
dealer.

13. Warranty / Liability

The SATA General Conditions of Sale and Delivery and further contractual
agreements, if applicable, as well as the valid legislation at the time apply.
SATA cannot be held responsible especially in the following
cases:
• When the operating instructions are disregarded.
• When the product is used in other than the intended ways of usage.
• When untrained staff is employed.
110
Cause
Cleaning solution
(water-based) remains
inside/on the spray
gun for too long.
Unsuitable cleaning
media
Defective or missing
paint needle sealing.
Clogged or damaged
paint needle.
Contamination be-
tween paint needle tip
and fluid tip
Damaged nozzle set.
Corrective Action
Cleaning, observe
chapter 8, get a
replacement spray
gun body.
Replace / insert paint
needle sealing, chap-
ter 9.3
Replace nozzle set,
chapter 9.1; replace
paint needle sealing, if
necessary, chapter 9.3
Clean fluid tip and
paint needle, observe
chapter 8
Replace nozzle set,
chapter 9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Minijet 3000 b t hvlp

Tabla de contenido