NOVAMASTER RF LOGIC (TIMER-RF)
USER GUIDE
RF TIMER & RF CONNECTING BOXES
CHARACTERISTICS
Wireless communication by radio signal
from the RF thermostat to the active an-
tenna and to the RF Timer.
Range of approximately 50m in residen-
tial environment.
7 day program
9 Built-in programs and 12 User pro-
grams
Program graphic display
Room temperature and time display
Auto or Manual (Comfort / Reduced /
Anti-freeze) operation
TIMER RECEIVER DISPLAY
1 : Zone Heating
2 : Holiday function activated
3 : Operating mode menu
4 : Day of the week
5 : Time or set temperature
6 : Current day graphic program
7 : If lit-up 10 display the current room temperature
8 : Zone number or room temperature
MODES DESCRIPTION
&
Use
keys to change the mode in the operating mode menu.
In
,
, or
modes, by pressing
day program of the displayed zone.
Use
/
to change the displayed zone and move the green blinking cursor on Master/SB
display.
Set CLOCK Menu:
Use this menu to adjust the clock to the actual
time.
use
/
to
adjust minutes
Press
use
/
to
adjust hours
Press
Use
/
to
adjust day
Press
COMFORT operating mode:
Force comfort temperature operation indefinitely
(for a few hours or days, see holiday function).
The RF TIMER regulation will now follow the
thermostat set temperatures.
AUTOMATIC operating mode:
RF TIMER will follow automatically the zone
programs according to the actual time
= Thermostat set temperature
= Thermostat set temperature - 4°C
GB
Possibility to combine
6 or 10 zones.
Holiday function
Reset function
program memory infinite (non volatile)
Time kept during 3 hours without power
Installation parameters: Prog/easy pro-
gram, Buzzer Alarm, Pump/actu Exercise,
ITCS function (Intelligent Temperature
Control System), etc...
you can see the room set temperature and actual
REDUCED operating mode:
Force reduced temperature operation indefi-
nitely (for a few hours or days, see holiday
function).
The RF TIMER regulation will now follow the
thermostat set temperature -4°C.
ANTI FREEZE operating mode:
Prevent your installation from freezing.
By pressing
/
keys the anti freeze
temperature starts to blink and can be adjust-
ed.
Now the TIMER RF will keep the temperature
above freezing in each zone.
OFF mode :
Use this mode if your Heating installation
needs to be turned OFF.
The RF TIMER will switch off the installation
and then switch itself OFF (blank screen).
User programs are saved in room volatile
memory, time is kept running for a few hours.
Press any key to wake up the RF TIMER.
Danger:
In this mode you installation can freeze
Because the TIMER-RF is stopped.
PROGRAM menu :
By pressing
/
keys the zone number starts to blink,
Then use
/
to
Select the zone or an user
program (see user program
edition).
If you select a zone number 01 to 12 and press
followed for this zone.
The program number:
start to blink
Shows the daily
program.
If you select a built in program "P1" to "P9" or a user program "U1" to "U4", and press
program will be followed in
mode.
Built-in programs description:
P1: Morning, Evening & Week-end
P2: Morning, Midday, Evening & Week-end
P3: Day & Week-end
P4: Evening & Week-end
P5: Morning, Evening (bathroom)
USER PROGRAM EDITION
The
key sets
temperature at the current blinking
The
key sets
temperature at the current blinking
Use
&
keys to slide the blinking cursor position in the day and modify or correct easily the program.
When the displayed day is correct press
When you press
on day 7 you return to the top menu.
Now your user program will be followed if you select this user program for a zone and put the RF TIMER in
operating mode.
SPECIAL FUNCTIONS
HOLIDAY Function:
With
&
keys, go to
function. Then select with
below 24h then in days (d). Then select a mode
The
logo is active and the number of hours/days left is displayed until the RF TIMER returns in
mode and continues to follow the zone programs.
MASTER and SB LED INDICATIONS
Green LED:
A green shining LED indicates a correct radio reception on the zone.
A green blinking cursor can also appear to show the current zone selected.
In RF Initialization the zones selected with a green LED will be assigned (See RF Initialization section)
Red LED:
When RED is lit up, the zone is currently heating (actuator open).
When extinct, the zone is not heating (actuator closed).
Lost Thermostat Reception Alarm:
When a RED light blinks (1 blink/second) on the MASTER / SB display, indicates that this zone is in
radio reception alarm.
The RF Thermostat radio signal from this zone has been lost since more than 15 minutes.
If the installation parameter 'F.1 Buzzer alarm' is selected and if one or more zones are disconnected,
there is an alarm tone.
Use
&
to see the
Programm anzeigen.
other days in the program
Program number
Shows the daily program
, you can then select a weekly program to be
Use
&
other days in the program.
Use
/
to select a
program number.
P6: Morning, Afternoon & Week-end
P7: 7h - 19h (Office)
P8: 8h - 19h, Saturday (Shop)
P9: Week-end (Secondary House)
Day
Hour at the cursor position
program hour
program hour
to jump to the following day.
/
keys the delay in hours (H) if
or
or
.
Instruction RF Logic GB_PPLIMW15041Ab
to see the
, then this