5. Run and operation explanation for inverter
Fig.5-7 indicación del estado de espera ejemplo de funcionamiento
02. Function code parameter setting
Take function code F01.01 modified from 5.00Hz to 6.00Hz as example.
Boldface in Fig.5-8 shows flickering digit.
Fig.5-8 Ejemplo de parametrización y modificación de parámetros
Description: under second -class menu: if the parameter has no blinking digit,
this function code can't be modified, possible reasons are as follows:
1> This function code shouldn't be modified: for example actual detected
status parameter: run record parameter etc.;
2> This function code can't be modified under run status and can be changed
after stopping running;
3> Parameter protected. All the function code can't be modified when function
code F00.14=1 or 2, in order to avoid wrong operation. Need to set the function
code F00.14 to 0 if you want to edit function code parameter.
163