F02.21
Foreward/Reverse
switching mode
F02.22
Energy consumption
braking selection
F02.23
Energy consumption
braking voltage
F02.24
Energy consumption
braking use rate
F02.25
Reserved
F02.26
Reserved
Function
Name
Code
F03.00
V/F curve setting
F03.01
Torque boost mode
F03.02
Torque boost
F03.03
Torque
boost
frequency
F03.04
V/F frequency value 0
F03.05
V/F voltage value 0
F03.06
V/F frequency value 1
F03.07
V/F voltage value 1
F03.08
V/F frequency value 2
F03.09
V/F voltage value 2
F03.10
V/F frequency value 3
F03.11
V/F voltage value 3
F03.12
V/F oscillation
suppression factor
Function
Name
Code
F04.00
Jump freq. 1
F04.01
Jump freq. 1 range
F04.02
Jump freq. 2
F04.03
Jump freq. 2 range
F04.04
Jump freq. 3
F04.05
Jump freq. 3 range
F04.06
Slip freq. gain
176
0: Over zero switchover
1: Over starting frequency switchover
0: No energy consumption braking
1: Energy consumption braking.
115.0~145.0% (rated busbar voltage)
0.0~100.0%
F03-V/F
control parameter group
Set Range
0: Constant torque curve
1: Degression torque curve 1 (2.0 power)
2: Degression torque curve 1 (1.7 power)
3: Degression torque curve 3 (1.2 power)
4: User self-defined setting V/F curve (Confirmed
by F03.04~F03.11)
0: Manual boost.
1: Auto torque boost
0.0~12.0%
cut-off
0.0~100.0% (motor rated frequency)
0.00~V/F frequency value 1
0.00~V/F voltage value 1
V/F frequency value 0~V/F frequency value 2
V/F voltage value 0~V/F voltage value 2
V/F frequency value 1~V/F frequency value 3
V/F voltage value 1~V/F voltage value 3
V/F frequency value 2~upper limit frequency
V/F voltage value 2~100.00%( motor rated
voltage)
0~255
F04-Auxiliary running parameter group
0.00Hz~upper limit frequency
0.00Hz~upper limit frequency
0.00Hz~upper limit frequency
0.00Hz~upper limit frequency
0.00Hz~upper limit frequency
0.00Hz~upper limit frequency
0.0~300.0%
Set Range
1
0
×
1
0
o
0.1%
125.0%
o
0.1%
50.0%
o
Min.
Factory
Modifi
Unit
Default
-cation
1
0
×
1
0
o
0.1%
Base on
o
motor
type
0.1%
20.0%
o
0.01Hz
10.00Hz
×
0.01%
20.00%
×
0.01Hz
20.00Hz
×
0.01%
40.00%
×
0.01Hz
25.00Hz
×
0.01%
50.00%
×
0.01Hz
40.00Hz
×
0.01%
80.00%
×
1
10
o
Min.
Factory
Modifi
Unit
Default
-cation
0.01Hz
0.00Hz
×
0.01Hz
0.00Hz
×
0.01Hz
0.00Hz
×
0.01Hz
0.00Hz
×
0.01Hz
0.00Hz
×
0.01Hz
0.00Hz
×
0.1%
0.0%
×