F08.28
Specify internal count
to setting
F08.29
Internal timer timing
setting
F08.30
Terminal pulse encoder
frequency rate
F08.31
Reserved
Function
Name
Code
F09.00
Open collector output
terminal Y1 output
setup
186
0~65535
0.1~6000.0s
0.01~10.00Hz (only be effective by given X1:X2
encoder)
F09-on-off, analog output function parameter group
Set Range
0:terminal unused
1:operation(RUN)
2:CW run
3:CCW run
4:DC brake
5:run prepare finish(busbar voltage normal,
fault free, no run forbid, receival of run
command's status)
6:stop command indication
7:no current detected
8:overcurrent detected
9:current1 arrival
10:current2 arrival
11:no frequency output
12:frequency arrival signal(FAR)
13:frequency level detect signal 1(FDT1)
14:frequency level detect signal 2(FDT2)
15:output frequency arrival upper limit(FHL)
16:output frequency arrival low limit(FLL)
17:frequency 1 arrival output
18:frequency 2 arrival output
19:overload pre-alarm signal(OL)
20:undervoltage lockout stop (LU)
21:external fault stop(EXT)
22:fault
23:alarm
24:simple PLC operation
25:simple PLC section operation finish
26:simple PLC circle operation finish
27:simple PLC operation stop
28:traverse frequency high and low limit
29:setup length arrival
30:internal counter final value arrival
31:internal counter designated value arrival
32:internal timer arrival---output 0.5s valid
signal on arrival
33:operation stop time finish
34:operation arrival time finish
35:setup run time arrival
36:setup power on time arrival
1
0
o
0.1s
60.0s
o
0.01Hz
1.00Hz
o
Min.
Factory
Modifi
Unit
Default
-cation
1
0
×